WARNING
• Please read the instructions of both manuals before installing and using the unit.
• Legal instructions are located at the beginning of user manual.
• For detailed technical informations, please read the supplied Product Fiche, and
consult http://www.erp-equation.com/ac/
INSTALLATION
Indoor/Outdoor Unit Installation Drawings
• The models adopt HFC refrigerant R32.
more than 15cm
more than 10 cm
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
• The marks from A to G in
the figure are the parts
numbers.
• The distance between
the indoor unit and the
floor should be more
than 2m.
• If using the left side drain pipe, make sure the hole is got through.
• The above indoor and outdoor units' picture is just for your reference.
• Please be subject to the actual product purchased.
Attention must be paid to
the rising up of drain hose
more than 10 cm
A
more than 20 cm
more than
20 cm
more than 60 cm
1 Air outlet
2 Air inlet
3 Connecting piping and electrical
wiring
4
4 Drin hose
4
Compressor (Inside of Unit)
G
Optional parts for piping
G
A Non-adhesive tape
B Adhesive tape
C Saddle (L.S) with screws
D Connecting electric cable for indoor
and outdoor
F
E Drain hose
F
F Heating insulating material
A
G Piping hole cover
C
C
Fixing of outdoor unit
• Fix the unit to concrete or block
with bolts (10mm) and nuts fir-
mly and horizontally.
• When fitting the unit to wall sur-
D
face, roof or rooftop, fix a suppor-
D
ter surely with nails or wires in
E
consideration of earthquake and
E
strong wind
• If vibration may affect the house,
fix the unit by attaching a vibra-
tion-proof mat.
more than 25 cm
Bi-split connection
A
B
FR
ES
PT
IT
EL
PL
RU
KZ
UA
RO
EN
123