Installation instructions, only for experts

6.3. Operating time

DIP-Bank 1
Function selection switch 5 - 8
The maximum operating time is set to
6 hours as standard. The infrared con-
troller shuts down automatically after the
maximum heating period for safety reasons.
The function selection switch in the low-
voltage connection area can be adjusted to
the maximum operating time. The required
positions of the function selection switch
can be found in the following table.
!
The EN 60335-2-53 specifies a maximum heating period limit of 6 hours
for private saunas. For saunas in hotels, apartment blocks and similar
locations, a maximum heating period limit of 12 hours is permissible.
Extending the heating period limit to 18 hours or 24 hours is only per-
mitted in public saunas.
Time
5 min.
10 min.
15 min.
30 min.
45 min.
60 min.
Fig. 11: Operating time
Function selection switch
5
6
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
p. 21/32
7
8
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF