Ground-fault Circuit Interrupter (GFCI) Verification
It is important to verify the ground-fault circuit interrupter
installation and operation on a monthly basis.
GFCI verification procedure
1- Increase the temperature set point until the heating power
bars are displayed (displayed in the bottom-right hand corner
of the screen).
2- Press down the Test button.
3- The following two cases can occur:
a) Successful test: The red indicator of the thermostat lights
up. In this case, press down once again the Test button
to reinitialize the ground-fault circuit interrupter, the red
indicator turns off.
b) Failed test: The red indicator does not light up and the entire
display blinks during 5 seconds. In this case, disconnect
the heating system at the electrical panel and call
Schluter
Security mode
This mode imposes a maximum temperature set point which
is impossible to exceed regardless of the mode in progress.
However, it is still possible to lower the set point at your
discretion. The programming of the Auto and Pre-Prog modes
also respects this maximum temperature set point. Please note
that when the Security mode is activated, it is impossible to
switch from the
-Systems' customer service.
®
mode to the
mode, and conversely.