Technical Specifications - aerauliqa Quantum AX Manuel D'instructions

Masquer les pouces Voir aussi pour Quantum AX:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

verified by contact with the Test Finger (test probe "B" of the norm EN61032) in
compliance with the current safety regulations.
• Ceiling installation
In order to guarantee the IPX4 degree of protection against moisture in case of
ceiling installation, use the appropriate ceiling mount kit, which is not included. Use
only the rear entry hole for supply cables. If there is a possibility of condensation
along the air discharge duct, provide a drainage system to prevent condensation
from discharging into the environment through the fan.
Attention: do not mount the product on the ceiling without this kit.
• Window installation
In case of window installation it is necessary to use the appropriate window kit,
which is not included.
Attention: do not mount the product on the window without this kit.
INTRODUCTION
Quantum A X is a decentralised mechanical ventilation unit designed to ensure air extraction in small/medium-
sized rooms.
Suitable for air discharge directly to the outside or in the presence of short ducted system. Wall, ceiling or
window installation (fig. 1).

TECHNICAL SPECIFICATIONS

• Material: High quality, impact and UV-resistant ABS colour RAL 9010.
• Design front cover removable for cleaning without the use of tools.
• Rear reinforcement ring to prevent spigot deformation during installation.
• High efficiency aerodynamic fan with "winglet" blades to optimise quietness and efficiency.
• Single phase EC Brushless motor with integral thermal protection.
• Motor mounted on high quality ball bearings.
• The fan is double insulated: no earth connection is required.
• Trickle speed selectable during installation.
• Option to boost from trickle (or from off) through LS connection.
• Installation type selection available (through wall or ducted).
• IPX4 degree of protection.
• Power supply 220-240V~ 50Hz.
VERSIONS
BASIC
The fan runs continuously at selected trickle speed (set by the jumper switch combination fig. 15) and can be
boosted with a dedicated ON/OFF switch (or PIR, CO2...sensor) or with a light switch (fig. 13A). Trickle speed
can be set to off (fig. 15).
WITH HUMIDISTAT/TIMER
The fan is equipped with a humidity sensor, whose threshold is adjustable from 50% to 95% Relative
Humidity via dedicated trimmer, and with a timer which is adjustable from 0 to approx. 30 minutes via
dedicated trimmer (fig. 14B).
The fan runs continuously at selected trickle speed (set by the jumper switch combination fig. 15), increases
its speed in case the percentage of Relative Humidity exceeds the settable threshold, and can anyway be
boosted with a dedicated ON/OFF switch (or PIR, CO2...sensor) or with a light switch (fig. 13B). Trickle
speed can be set to off (fig. 15).
To deactivate the humidistat function, turn the trimmer HY completely clockwise.
Automatic humidistat operation: when the percentage of Relative Humidity exceeds the settable threshold,
fan speed automatically increases to "comfort boost" speed, (intermediate between the selected trickle
speed and the boost speed). When the percentage of Relative Humidity goes below the threshold, the fan
continues to function at "comfort boost" speed for a factory set period of time then returns to selected trickle
speed.
6

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Quantum ax 100Quantum ax 100htQuantum ax 150ht

Table des Matières