Technical Data; Control Box; Alarm Unit - SFA SANICUBIC 1 Manuel D'utilisation / D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

US/CAN

3.5 Technical data

Submersible pumping stations for blackwater
SANICUBIC® 1
Type of current
Power/Electrical information
Motor - Pump
Type of pump
Cable station – control box
Control box cable – socket
Protection Station:
SANICUBIC® 1:

Control box:

Max. recommended height
Max. flow
Max. temperature of incoming wastewater
Tank volume
Usefull volume
Height of low inlets (from the ground)
Gross Weight [lbs]
Waste pipe
Inlet
Ventilation
Flow curve
SANICUBIC® 2
Type of current
Power/Electrical information
Motor - Pump
Type of pump
Cable station – control box
Control box cable – socket
Protection
Station:
Control box:
Max. recommended height
Max. flow
*Both motors in operation
Max. temperature of incoming wastewater
Tank volume
Usefull volume
Height of low inlets (from the ground)
Gross Weight [lbs]
(including packaging and accessories) SANICUBIC® 2: 78 lbs
Waste pipe
Inlet
Ventilation
Single-phase
120V/60Hz/10A/1300W
or 220-240V/60Hz/6A/1500W
Thermal overload
protection
Class F insulation
Grinder blade
13 feet - H07RN-F-4 G 1.5
8 feet - H05VV-F-3 G 1.5
IP68
IPX4
36 feet
50 Gal/Min
158 °F (Max. 5 min.)
8.5 gallons
2.6 gallons
5 1/2''
44 lbs
Ø 1 1/2''
Ø 1 1/2'' or 4''
Ø 1 1/2''
Single-phase
220-240V/60Hz/13A/
2 x 1 HP
Oil bath cooled
Thermal overload
protection
Class F insulation
Grinder blade
13 feet - H07RN-F-4 G 1.5
8 feet - H05VV-F-3 G 1.5
IP68
IPX4
36 feet
90 Gal/min
158 °F (Max. 5 min.)
12 gallons
4.6 gallons
5 1/2''
Ø 1 1/2''
Ø 1 1/2'' or 4''
Ø 1 1/2''
4
Flow curve
3.6 Control box
Submersion of the control device
Risk of death by electric shock
w Only use the control device in rooms safe from floods
SANICUBIC® remote control box
• Pump control and monitoring cabinet integrated into a compact plastic housing
• For 1 or 2 pumps
• Option of forced mode
3.6.1 Electrical characteristics
Table 3: Electrical characteristics of the control box
Parameter
Value
Nominal power
supply
120V or 220-240V
Network frequency
60 Hz
Protection index
IPX4
Nominal current per engine
SANICUBIC 1 : 6A (220-240V version) or 10A (120V version)
SANICUBIC 2 : 13A
3.6.2 Technical characteristics of the detection device
Analog level sensor:
• Input voltage 0 - 5 V
Process outputs:
• One potential-free signalling output (250 V, 16 A) NO Contact
• One signalling output for the wired alarm unit that comes with the device
(except SANICUBIC® 2): 5V, 50mA
3.6.3 Dimensions of the remote control box

3.7 Alarm unit

3.7.1 Technical characteristics of the alarm device
SANICUBIC® alarm unit:
Wired alarm unit
16' cable
Audio and visual information
Protection index: IP20
3.7.2 Dimensions of the remote alarm unit

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sanicubic 2

Table des Matières