Technical Data - SFA SANICUBIC 1 Notice De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
UK

3 .5 Technical data

Pumping station for blackwater (submersible for the SANICUBIC® 1 WP,
SANICUBIC® 2 Classic, SANICUBIC® 2 Pro, SANICUBIC® 2 XL versions).
SANICUBIC® 1 / SANICUBIC® 1 WP
Type of current
Voltage
Frequency
Motor - Pump
Type of pump
Motor power consumption (for one motor)
Maximum absorbed current
Cable station – control box
Control box cable – socket
Protection Station:
SANICUBIC® 1:
SANICUBIC® 1 WP:
Control box:
Max. recommended height
Max. flow
Max. temperature of incoming wastewater
Tank volume
Usefull volume
Height of low inlets (from the ground)
Gross Weight [KG]
(including packaging and accessories) SANICUBIC® 1 WP: 26.7
Waste pipe
Inlet
Ventilation
SANICUBIC® 1 flow curve; SANICUBIC® 1 WP
discharge height (m)
12
9
6
3
0
0
5
SANICUBIC® 2 Classic / SANICUBIC® 2 Pro
Type of current
Voltage
Frequency
Motor - Pump
Type of pump
Motor power consumption (for one motor)
Maximum absorbed current
Cable station – control box
Control box cable – socket
Protection
Station:
Control box:
Max. recommended height
Max. flow
Max. temperature of incoming wastewater
Tank volume
Usefull volume
Height of low inlets (from the ground)
Gross Weight [KG]
SANICUBIC® 2 Classic: 35.5
(including packaging and accessories) SANICUBIC® 2 Pro: 33.0
Single-phase
220-240V
50/60 Hz
Oil bath cooled
Thermal overload
protection
Class F insulation
Shredding by
blade-plate
1,500 W
6 A
4 m - H07RN-F-4 G 1.5
2.5 m - H05VV-F-3 G 1,5
IP67
IP68
IPX4
11 m
12 m³/hour
70°C (Max. 5 min.)
32 L
10 L
140 mm
SANICUBIC® 1:
19.8
Ø ext. 50 mm
Ø ext. 40, 50, 100, 110 mm
Ø ext. 50 mm
10
15
flow (m
/h)
3
Single-phase
220-240V
50/60 Hz
Oil bath cooled
Thermal overload
protection
Class F insulation
Shredding by
blade-plate
1,500 W
13 A
4 m - H07RN-F-4 G 1.5
2.5 m - H05VV-F-3 G 1,5
IP68
IPX4
11 m
12 m³/hour
70°C (Max. 5 min.)
45 L
17.5 L
140 mm
Waste pipe
Inlet
Ventilation
SANICUBIC® 2 Classic flow curve; SANICUBIC® 2 Pro
discharge height (m)
12
9
6
3
0
0
Type of current
Voltage
Frequency
Motor - Pump
Type of pump
Motor power consumption (for one motor)
Maximum absorbed current
Cable station – control box
Control box cable – socket
Protection
Station :
Control box:
Max. recommended height
Max. flow
Max. temperature of incoming wastewater
Tank volume
Usefull volume
Gross Weight [KG] (including packaging and accessories)
Waste pipe
Inlet
Ventilation
SANICUBIC ® 2 XL Single-phase discharge bend
discharge height (m) - Hf(Qv) Bend on XL, Fos, Cubic 1&2
16
Qmini
14
DN 80
12
10
8
6
4
2
0
0
5
10
Self-cleaning speed limit: 0.7 m/s
SANICUBIC ® 2 XL Three-phase
Type of current
Voltage
Frequency
Motor - Pump
Type of pump
Motor power consumption (for one motor)
Maximum absorbed current
Cable station – control box
Control box cable – socket
22
Ø ext. 50 mm
Ø ext. 40, 50, 100, 110 mm
Ø ext. 50 mm
5
10
15
flow (m
3
/h)
SANICUBIC® 2 XL
Single-phase
220-240V
50/60 Hz
Oil bath cooled
Thermal overload
protection
Class F insulation
Vortex Impeller
(clearance: 50 mm)
2,000 W
16 A
4 m - H07RN-F-4 G 1.5
2.5 m - H05VV-F-3 G 1,5
IP68
IPX4
10 m (DN80)
7 m (DN100)
40 m³/hour
70°C (Max. 5 min.)
120 L
26 L
101.0
ND 100 (Ø ext. 110 mm)
or ND80 (Ø ext. 90 mm)
Ø ext. 40, 50, 100, 110 mm
Ø ext. 50 mm
Qmini
DN 100
15
20
25
30
35
40
flow (m
/h)
3
Three-phase
230-400V
50/60 Hz
Oil bath cooled
Thermal overload
protection
Class F insulation
Vortex Impeller
(clearance: 50 mm)
3,500 W
12 A
4 m - H07RN-F-4 G 1.5
2.5 m - H05VV-F-5 G 2.5

Publicité

Table des Matières
loading

Table des Matières