Control Box; Electrical Characteristics; Technical Characteristics Of The Detection Device; Dimensions Of The Remote Control Box - SFA SANICUBIC 1 Notice De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 3
UK
Protection
Station:

Control box:

Max. recommended height
Max. flow
Max. temperature of incoming wastewater
Tank volume
Usefull volume
Height of low inlets (from the ground)
Waste pipe
Inlet
Ventilation
SANICUBIC ® 2 XL Single-phase discharge bend
discharge height (m)
18
16
14
12
10
8
6
4
2
0
0
10
20
30
3 .6 Control box
Submersion of the control device
Risk of death by electric shock
w Only use the control device in rooms safe from floods
SANICUBIC® remote control box
• Pump control and monitoring cabinet integrated into a compact plastic housing
• For 1 or 2 pumps
• Option of forced mode

3 .6 .1 Electrical characteristics

Table 3: Electrical characteristics of the control box
Parameter
Value
Nominal power
supply
1 ~ 220-240 V AC
Network frequency
50/60 Hz
Protection index
IPX4
Nominal current per engine
SANICUBIC® 1; SANICUBIC® 1 WP;
SANICUBIC® 2 Classic; SANICUBIC® 2 Pro
SANICUBIC® 2 XL Single-phase
SANICUBIC® 2 XL Three-phase

3 .6 .2 Technical characteristics of the detection device

Analog level sensor:
• Input voltage 0 - 5 V
Process outputs:
• One potential-free signalling output (250 V, 16 A) NO Contact
• One signalling output for the wired alarm unit that comes with the device
(except SANICUBIC® 2 Pro): 5V, 50mA

3 .6 .3 Dimensions of the remote control box

IP68
IPX4
14.5 m (DN80)
13 m (DN100)
55 m³/h
70°C (Max. 5 min.)
120 L
26 L
102.0
DN 100 (Ø ext. 110 mm)
or DN80 (Ø ext. 90 mm)
Ø ext. 40, 50, 100, 110 mm
Ø ext. 75 mm
40
50
60
70
flow (m
3
/h)
6 A
8 A
6 A

3 .7 Alarm unit

3 .7 .1 Technical characteristics of the alarm device

SANICUBIC® alarm unit:
SANICUBIC® 1; SANICUBIC® 1 WP; SANICUBIC® 2 Classic; SANICUBIC® 2 XL:
Wired alarm unit
5m cable
Audio and visual information
Protection index: IP20
SANICUBIC® 2 Pro:
HF alarm unit 868 MHz (radio)
Unobstructed range: 100 m
Audio and visual information
Protection index: IP20

3 .7 .2 Dimensions of the remote alarm unit

3 .7 .3 Option of connection to an external alarm

Option of externalising the alarm signal (depending on the model). Dry
contact (no voltage) NO (normally open) operated by a max. 250V/16A relay.
The terminals can be connected to a powered system.
This contact closes as soon as the station is in alarm mode (except in the case
of area alarm) and remains closed as long as the alarm sounds.
External alarm
Max. 250 V / 16A

3 .8 Sump tank

The sump tank is designed for pressure-free operation. Wastewater is collec-
ted there at atmospheric pressure before being discharged to the sewer. The
ventilation duct allows the tank to always remain at atmospheric pressure

3 .9 Pumped fluids

Pumping unauthorised fluids
Dangerous for people and the environment!
w Only discharge authorised pumped fluids in the public sewerage
network
Authorised pumped fluids:
The following liquids are allowed in discharge systems:
Water contaminated by domestic use, human excrement.
Unauthorised pumped fluids:
The following liquids and substances are banned:
• Solid materials, fibres, tar, sand, cement, ash, coarse paper, hand towels,
wipes, cardboard, rubble, rubbish, slaughterhouse waste, oils, greases,
etc.
• Wastewater containing harmful substances (for example, untreated
greasy waste from restaurants). Pumping these liquids and substances
requires the fitting of a compliant grease trap.
• Rain water.

3 .10 Noise level

The noise level depends on the fitting conditions and operating point. This
sound pressure level Lp is less than 70 dB (A).
23
Dry contact
NO

Publicité

Table des Matières
loading

Table des Matières