Figure 2: Ventilation of the SANICUBIC® control box
6.1.1. Operation of the SANICUBIC® 1 control remote box (IP68)
1/ General alarms:
Level alarm:
If the water level inside the device is abnormally high, the alarm LED lights
up red + engine starts up. Furthermore, if this LED flashes red, it indicates a
detection problem for the normal water level (Long dip tube).
Time alarm:
If the motor runs continuously for more than 1 minute, the red alarm LED
lights up.
2/ Alarm reset: The button on the keypad will only allow you to turn off the
red LED (it will turn green) if the problem that triggered the alarm has been
resolved. It also allows you to stop the ringing of the remote alarm control.
Mains alarm:
- If the LED is off, there is no power supply.
- When the device is powered on again, the LED flashes green, indicating
that the mains voltage has temporarily disappeared.
6.1.2 Operation of the SANICUBIC® 2
OPERATION OF THE ALARM
1/ General alarms:
Level alarm:
If the water level inside the device is abnormally high: the siren is triggered
+ the red alarm LED lights up + both motors start-up. If this LED flashes red,
it indicates a detection problem for the normal water level (Long dip tube).
Time alarm:
If one of the two motors runs for more than 1 minute: the siren is triggered
+ the red alarm LED lights up + the other engine starts-up.
Mains alarm:
In case of power failure (or when unplugging the device): the siren is trigge-
red + the red alarm LED lights up + the yellow mains LED blinks.
2/ General alarm reset:
If the problem that triggered one of the alarms above disappears, the siren
stops, but the red alarm LED remains lit as a reminder of the fact that the
system encountered a problem. Either of the two keypad keys will stop the
siren in all cases, but it will only turn off the red LED if the problem that
triggered the alarm has been resolved. Alarms from the remote box will also
remain active until the problem has been solved. This prevents the system
from being «abandoned» by default.
6.2 SANICUBIC® alarm unit
To wall mount the unit, use the following figure as a guide:
6.2.1 Operation of the SANICUBIC® 1 / SANICUBIC® 2 wired alarm unit
The SANICUBIC® alarm unit does not require a separate power supply. The
power is supplied through the SANICUBIC®. In case of power failure, the
alarm unit's battery takes over.
Connection of the alarm unit to the device:
Connect the alarm cable directly to the unit.
1/ The red general alarm LED reproduces
the operation of the red LED on the base
card. The alarm unit sounds in the event
of an alarm as long as the fault is present.
To stop the alarm, press the reset (*)
button on the device's keypad or the
button under the alarm unit.
2/ The yellow «mains» LED indicates the
power status of the alarm unit
-Steady light = live SANICUBIC® connected
to the mains supply
-Flashing = power failure on the SANICUBIC®
1
Table 5: SANICUBIC® 1 / SANICUBIC® 2 alarm unit
1
Red general alarm LED
2
Yellow mains alarm LED (power supply indicator)

6.3 Messages and faults

Table 7: Messages and faults:
Alarm on the device SANICUBIC® 1: Green LED: station live
Alarm on the device SANICUBIC® 2: Yellow LED: station live
ANOMALY DETECTED
CAUSES PROBLEMS
• Water level detection
Flashing red alarm LED
system faulty
• Clogged vent pipe
Steady red alarm LED
• Clogged drain line
• Blocked or out of order
pump
• Discharge too high or
excessive inflow
• Mains failure
LED off
• Faulty electronic board
7
Reset (*) :
2
SOLUTIONS
• Consult SANIFLO
after-sales service
• Check that air flows
freely in both directions
in the vent pipe
• Go over the installation
again
• Consult SANIFLO
after-sales service
• Check the electrical
system
• Consult SANIFLO
after-sales service