DESCRIPTION

3.1 General description

This device is a compact pumping station. SANICUBIC® 1 is a pumping
station specially developed for individual use (detached house or small
commercial premises). SANICUBIC® 2 is a pumping station specially
developed for individual, commercial and small community use (small
buildings, shops, public places).

3.2 Scope of supply

Depending on the model, the following components are provided:
• Sump tank with 1 or 2 pumps and 3 level sensors
• Wired remote control box
• Wired alarm unit
• Check valves
• Mounting kit (screws, pegs)
• Connecting sleeves for inlet, discharge and ventilation piping
• Clamps for the connecting sleeves

3.3 Rating plate

Examples:
Pumping station
1
4
1
Name of the lifting station
2
Power supply
3
Frequency
4
Protection index
5
Date of production
6
Identification number
7
Type of certification
Control box
2
1
1
Name of the pumping station
2
Name of the control box
3
Power supply
4
Phase type
5
Frequency
6
Protection index
7
Date of production
2
3
5
6
7
4
3
5
6
7

3.4 Design and operating mode

9
1
5
8
6
Table 2: SANICUBIC® 1
1
Inlet
2
Inlet
3
Waste pipe
4
Ventilation opening
5
Level sensor (dip tube)
6
Tank
7
Access panel
8
Control opening
9
Built-in check valve
10 Motor-pump assembly
11
Shredding system
The pumping station is equipped with several horizontal and vertical inlet
openings for 1 1/2'' or 4'' outside diameter piping (1) and 1 1/2'' outside
diameter piping (2). The engine-pump assembly (10) carries the pumped
fluid in the vertical discharge piping with an outside diameter of 1 1/2'' (3).
The ventilation duct (4) allows the tank to always remain at atmospheric
pressure.
Operating mode:
Effluents enter the pumping station through the horizontal and vertical
inlet openings (1) (2). They accumulate in a gas-tight, smell-proof and
watertight plastic tank (6). Controlled by a level sensor (5) and a control
box, effluents are shredded by the shredding system (11) and automatically
pumped, when they reach a certain level in the tank, by one or two pumps,
depending on the model, (10) above the back-flow level to flow into the
discharge line.
- SANICUBIC® 1 contain one pump equipped with a high-performance
shredding system. Sanicubic1 activation level: 5.5" of water.
- SANICUBIC® 2 contain two independent pumps. Each of these pumps is
equipped with a high-performance shredding system. Both pumps operate
each in turn, alternately. In case of abnormal operation, both engines run
simultaneously (or if one pump fails, the other takes over). Sanicubic2
activation level: 7.1" of water.
Level sensor / Dip tube:
• 2 Long dip tubes
During normal operation, as soon as the effluents reach the long tube's
actuation level in the tank, the pumping system switches on.
• Short dip tube
During abnormal operation, if the effluents reach the highest level in the
tank (short tube), an audible and visual alarm system is activated and the
pumping system switches on (if it is not faulty).
Alarm activation for Sanicubic 1 is 8.3" of water, activation level for
Sanicubic 2 is 9.4" of water.