12 Device Information

1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529
2.3
Installation Location
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Brine (heat source)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water (flow/return flow)
3.3
Heat output / COP
3.4
Sound power level
3.5
Heating water flow with an internal pressure differential of m³/h / Pa
3.6
Free compression of heat circulating pump (max. level)
3.7
Brine throughput with an internal pressure differential
(heat source) of
3.8
Free compression of brine circulating pump (max. level) Pa
3.9
Refrigerant; total filling weight
3.10 Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
Nominal current B0 W35 / cos 
5.4
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
1. This data indicates the size and capacity of the system. For an analysis of the economic and energy efficiency of the system, both the bivalence point and the regulation should
also be taken into consideration. The specified values, e.g. B10 / W55, have the following meaning: Heat source temperature 10 °C and heating water flow temperature 55 °C.
2. Note that additional space is required for pipe connections, operation and maintenance.
3. See CE declaration of conformity
4. The heat circulating pump and the heat pump manager must always be ready for operation.
www.dimplex.de
All manuals and user guides at all-guides.com
°C
°C
at B0 / W35
K
1
at B-5 / W55
kW / ---
1
at B0 / W50
kW / ---
1
at B0 / W35
kW / ---
dB(A)
Pa
m³/h / Pa
type / kg
type / litres
2
H x W x L mm
Inch
Inch
kg
V / A
1
B0 W35
kW
A
A / ---
4
452231.66.11 · FD 9208
SIK 11ME - SIK 16ME
SIK 11ME
Compact
IP 20
Indoors
Up to 55
-5 to +25
Monoethylene glycol
25%
9.9
9.4 / 2.4
11.3 / 3.0
11.8 / 4.4
51
1.0 / 3500
65500
3.0 / 13000
40000
R407C / 2.0
Polyolester (POE) / 1.36
Polyolester (POE) / 1.90
1115  652  688
R 1¼" external
R 1¼" external
191
230 / 25
2.66
38
14.46 / 0.8
3
Yes
1
Internal
SIK 16ME
Compact
IP 20
Indoors
Up to 55
-5 to +25
Monoethylene glycol
25%
10
13.3 / 2.2
15.5 / 2.9
15.8 / 4.2
51
1,3 / 3500
43500
3.5 / 13000
34000
R407C / 2.3
1115  652  688
R 1¼" external
R 1¼" external
203
230 / 32
3.77
45
20.5 / 0.8
3
Yes
1
Internal
EN-11