Capacitance Measurements; Dc Current Measurements - koban KMIR-01 Mode D'emploi

Multimètre thermographique trms
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

KMIR-01

4.8. Capacitance Measurements

WARNING: To avoid electric shock, disconnect power to the unit under test and discharge
all capacitors before taking any capacitance measurements.
Remove the batteries and unplug the line cords.
• Set the rotary function switch to the Ω CAP
• Insert the black test lead banana plug into the negative COM jack. Insert the red test
lead banana plug into the positive V jack.
• Press the MODE key to switch the Capacitance functions.
• Read the capacitance value in the Display.
16
EN
position.
EN

4.9. DC Current Measurements

• Insert the black test lead banana plug into the negative COM jack.
• For current measurements up to 4000μA DC, set the function switch to the μA position
and insert the red test lead banana plug into the μA/mA jack.
• For current measurements up to 400mA DC, set the function switch to the mA position
and insert the red test lead banana plug into the μA/mA jack.
• For current measurements up to 10A DC, set the function switch to the 10A position
and insert the red test lead banana plug into the 10A jack.
• Press the MODE button to indicate "
" on the display.
• Read the current in the display.
KMIR-01
17

Publicité

Table des Matières
loading

Table des Matières