Télécharger Imprimer la page

Device Information - Dimplex SI 30TER+ Instructions D'installation Et D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

12 Device Information

1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529
2.3
Installation location
1
3
Performance data
3.1
Operating temperature limits:
Heating water flow
Cooling, flow
Brine (heat source, heating)
Brine (heat sink, cooling)
Antifreeze
Minimum brine concentration (-13 °C freezing temperature)
3.2
Temperature spread of heating water
(flow/return flow)
3
3.3
Heat output / COP
7
3.4
Cooling capacity / COP
3.5
Sound power level to EN 12102
3.6
Sound pressure level at a distance of 10 m
3.7
Heating water flow (minimum cooling water flow
with internal pressure differential)
3.9
Brine throughput with an internal pressure differential
(heat source) of
3.10 Flow rate of additional heat exchanger
with an internal pressure differential of
3.11 Refrigerant; total filling weight
3.12 Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions without connections
4.2
Device connections to heating system
4.3
Device connections to heat source
4.4
Device connections for hot water
4.5
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption/max. absorption B0 W35
5.3
Starting current with soft starter
5.4
Nominal current
5.5
max. power consumption of compressor protection
(per compressor)
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels / Controller internal/externa
7.3
Max. operating overpressure (heat source/heat sink)
1. Domestic hot water preparation via additional heat exchanger in parallel operation: The waste heat output and/or the attainable cylinder temperature is dependent on the respective
operating point (temperature level/performance level). The waste heat output falls as the cylinder temperature rises.
2. See output curves
3. The coefficients of performance for parallel hot water preparation are also achieved via additional heat exchangers.
4. This data indicates the size and capacity of the system to EN 14511(5K of B0/W35). For an analysis of the economic and energy efficiency of the system, the bivalence point and
the regulation, should also be taken into consideration. These specifications can only be achieved with clean heat exchangers. Information on the maintenance, start-up and op-
eration can be found in the respective sections of the installation and operating instructions. The specified values have the following meaning, e.g. B10/W55: Heat source temper-
ature 10 °C and heating water flow temperature 55 °C.
5. Operation with 2 compressors
www.dimplex.de
All manuals and user guides at all-guides.com
2
°C
°C
°C
°C
at B0 / W35
K
4
at B-5 / W55
kW / ---
kW / ---
4
at B0 / W55
kW / ---
kW / ---
4
at B0 / W35
kW / ---
kW / ---
4
at B20 / W9
kW / ---
4
at B20 / W7
kW / ---
4
at B20 / W18
kW / ---
kW / ---
4
at B10 / W7
kW / ---
4
at B10 / W18
kW / ---
kW / ---
dB(A)
8
db(A)
9
m³/h / Pa
m³/h / Pa
m³/h / Pa
type / kg
type / litres
10
H x W x L mm
Inch
Inch
Inch
kg
V / A
4 5
kW
A
5
B0 W35 / cos ϕ
A / ---
W
12
bar
SI 30TER+
Reversible with additional heat exchanger
IP 21
Indoors
Up to 55±2
+7 to +20
-5 to +25
+5 to +30
Monoethylene glycol
25%
5
22,0 / 2,0
11,1 / 2,1
6
5
24,9 / 2,2
6
12,8 / 2,3
5
28,6 / 3,8
15,2 / 4,2
6
5
35,3 / 5,3
6
18,2 / 6,1
44,6 / 6,2
5
6
23,6 / 7,5
6
21,0 / 8,6
46,7 / 7,4
5
6
25,4 / 9,5
4,7 / 2200
6,7 / 5300
4,0 / 20000
R404A / 8,1
Polyolester / 3,7
1660 x 1000 x 775
R 1 1/2" internal/external
R 2" internal/external
R 1" internal/external
400 / 20
7,53 / 11,6
13,59 / 0,8
2/ Internal
12
5
62
46
385
26
70
11
Yes
3,0
EN-11

Publicité

loading