Dimplex SI 10MER Instructions D'installation Et D'utilisation page 28

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SI 10MER
6
Complies with the European safety regulations
7
Additional model features
7.1
Water in device protected against freezing
7.2
Performance levels
7.3
Controller internal/external
7.4
Max. operating overpressure (heat source/heat sink)
1. These data indicate the size and capacity of the system according to EN 14511. For an analysis of the economic and energy efficiency of the system, the bivalence point and
controller should be taken into consideration. The specified values have the following meaning, e.g. B10/W55: Heat source temperature 10 °C and heating water flow temperature
55 °C. These specifications can only be achieved with clean heat exchangers. Information on maintenance, start-up and operation can be found in the respective sections of the
installation and operating instructions.
2. If necessary, the operating range can be extended to a brine inlet temperature of -10 °C. In this case, the minimum brine concentration must be adjusted to 30 %. (Freezing tem-
perature -17 °C). At brine inlet temperatures of -10 °C to -5 °C, flow temperature rising from 55 °C to 62 °C.
3. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
The specified sound pressure level represents the free sound area level. The measured value can deviate by up to 16 dB(A), depending on the installation location.
4. Note that additional space is required for pipe connections, operation and maintenance.
5. Tolerance range of -3 % to +10 %
6. See CE declaration of conformity
7. The heat circulating pump and the heat pump manager must always be ready for operation
EN-12
All manuals and user guides at all-guides.com
7
bar
452232.66.38 · FD 9405
6
yes
1
internal
3,0
www.dimplex.de