Error Display
Overtemperature on
inverter board radiator
Inverter board motor
overload/motor phase
loss
Inverter board
communication error
Inverter board power-
on reset error
Inverter board
overvoltage
Inverter board
undervoltage
Inverter board voltage
is too high
Read/write flash error
on inverter board
Inverter board error/
Inverter board
communication error/
Inverter board wake-up
error/Error with inverter
board communication
data
Other
Cause
1.
2.
1.
2.
3.
No
No
1.
1.
1.
1.
1.
2.
Restart the appliance. If
problem persists, please
contact the customer
service.
27
Solution
Place the washing
machine at room
temperature for
two hours and then
enable T12 for self-
calibration.
Change the computer
board.
Check the motor
wiring.
Change the computer
board.
Check whether there
is a blockage in the
system.
Check the power
system.
Check the power
system.
Check the power
system.
Change the computer
board.
Check the wiring
connections.
Check the variable
frequency motor,
computer board and
wiring connections..