11 Device information

1
Type and order code
2
Design
2.1
Manager
2.2
Installation location / degree of protection according to EN 60529
2.3
Antifreeze condensate tray / heating water
2.4
Performance levels
3

Operating limits

3.1
Heating water flow / return
Air (heat source)
4
Performance data / flow rate
4.1
Heating water flow rate / internal pressure differential
maximum
minimum
3
4.2
Heat output / COP
4.3
Sound power level according to EN 12102
Normal operation/reduced operation
4.4
Sound pressure level at a distance of 10 m(air outlet side)
Normal operation/reduced operation
4.5
Air flow
5
Dimensions, connections and weight
5.1
Device dimensions without connections
5.2
Device connections for heating system
5.3
Weight of the transport unit(s) incl. packaging
5.4
Refrigerant; total filling weight
5.5
Lubricant; total filling quantity
6
Electrical connection
6.1
Supply voltage; fuse protection
6.2
Control voltage; fuse protection
6.3
Starting current with soft starter
6.4
Nominal power consumption
A2 W35/ max. power consumption
6.5
Power consumption ventilator
6.6
Nominal current A2 W35 / cos
7
Complies with the European safety regulations
8
Additional model features
8.1
Type of defrosting
8.2
Max. operating overpressure (heat sink)
1. The heat circulating pump and the heat pump manager must always be ready for operation.
2. These data indicate the size and capacity of the system according to EN 14511 (5K at A7). For an analysis of the economic and energy efficiency of the system, other parameters,
in particular the defrosting capacity, the bivalence point and the regulation, should also be taken into consideration. These specifications can only be achieved with clean heat
exchangers. Information on the maintenance, start-up and operation can be found in the respective sections of the installation and operating instructions.
The specified values have the following meaning, e.g. A7 / W35: External air temperature 7 °C and heating water flow temperature 35 °C.
3. With maximum heating water flow.
4. The heat output is reduced by approx. 5 % in lower operation
5. The specified sound pressure level corresponds to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
6. See CE declaration of conformity
www.dimplex.de
°C
°C
2
m³/h / Pa
m³/h / Pa
at A-7 / W35
kW / ---
at A2 / W35
kW / ---
at A7 / W35
kW / ---
at A7 / W55
kW / ---
at A10 / W35
kW / ---
4
dB(A)
5
dB(A)
m³/h
H x W x L mm
Inches
kg
type / kg
type / litres
A
3
kW
W
A / ---
bar
452164.66.01 · FD 9211
LA 11TAS - LA 16TAS
LA 11TAS
External
Outdoor / IP24
1
Heated / yes
1
up to 58 ± 2 / from 18
-25 to +35
1.9 / 9200
1.3 / 4100
EN 14511
7.2 / 2.8
8.6 / 3.4
10.1 / 4.0
10.3 / 2.7
11.3 / 4.4
59 / 57
31 / 29
2500
1340 x 852 x 1050
R1"
193
R404A / 2.5
Polyolester (POE) / 1.5
3~/PE 400 V (50 Hz) / C13 A
- /-
15
2.50 / 4.1
up to 85
4.51 / 0.8
6
Reverse circulation
3,0
LA 16TAS
External
Outdoor / IP24
1
Heated / yes
1
up to 58 ± 2 / from 18
-25 to +35
2.6 / 11900
1.7 / 6300
EN 14511
10.0 / 2.7
11.7 / 3.2
14.6 / 3.7
14.4 / 2.7
16.6 / 3.9
62 / --
32 / --
4000
1550 x 852 x 1074
R1"
231
R404A / 3.5
Polyolester (POE) / 1.9
3~/PE 400 V (50 Hz) / C13 A
- /-
20
3.66 / 6.4
up to 180
6.60 / 0.8
6
Reverse circulation
3,0
EN-9