EINHELL HSP 41/1 Mode D'emploi page 16

Masquer les pouces Voir aussi pour HSP 41/1:
Table des Matières

Publicité

Anleitung HSP41-1_HSP51_SPK1
GB
14. Troubleshooting
The following table describes the possible problems which may arise when you use the wood splitter and
provides recommended remedial measures for dealing with them.
Problem
Motor fails to start
Motor circuit breaker has been
triggered
Trunk fails to split
Trunk is incorrectly positioned
Trunk exceeds permitted
dimensions
Wedge fails to cut
Oil leak
Pressure setting screw has been
displaced
The trunk pusher moves forward
Air in the oil circuit
with jolts or heavy vibrations
Escaping oil from the cylinder or
Ventilation screw not unscrewed
other point.
during operation.
Ventilation screw not screwed tight
during transportation
Oil drainage screw not screwed
tight
Oil seal is worn
16
14.09.2006
18:51 Uhr
Probable cause
Remedy
Allow the motor to cool down and
press in the motor circuit breaker
switch
Position the trunk correctly
Reduce the size of the trunk
Sharpen the wedge. Remove
burrs and nicks from the wedge
Contact an authorized dealer
Contact an authorized dealer
Check the oil level.
Top up if necessary.
If the problem remains, contact
an authorized dealer.
Unscrew the ventilation screw
Always tighten the ventilation
screw before transporting
Tighten the oil drainage screw
Contact an authorized dealer
Seite 16

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hsp 51

Table des Matières