INSTALLATIoN
Power supply
12.2 Low voltage, BUS cable
Xd04.1 Terminals, external low voltage
T(Puf)
Temperature sensor, buffer cylinder (function part of
the standard delivery)
T(WW)
Temperature sensor, DHW (function part of the stand-
ard delivery)
T(Kue/WW)
For cooling: flow sensor /
For solar connection: lower DHW sensor
T(2WE)
Temperature sensor heat source 2
Xd04.2 Terminals, external low voltage
T(KOLL)
Collector sensor
T(A)
Outside temperature sensor (function part of the
standard delivery)
T(MK)
Mixer circuit temperature sensor (function available as
optional extension)
Fernb.
FE 7 remote control (function available as optional
extension)
Xd05
CAN BuS terminal
+
(only in conjunction with FEK)
Ground
L
Low
H
High
www.stiebel-eltron.com
319204_HSBC_200_de_en_fr_nl_it.indb 43
Connecting BUS cables
Material losses
!
Bus cables, power cables and sensor leads must be in-
stalled separately.
f Install a J-Y (St) 2 x 2 x 0.8 mm² cable as bus to the heat
f
pump.
X5
A1
A1
WPM 3 heat pump manager
A2
Programming unit
A3
Heat pump
A3
A2
1.1
The
you
Con
X2 o
The
f A
f
HSBC |
43