Télécharger Imprimer la page

Honeywell RTH5160 Serie Guide D'installation Rapide page 9

Publicité

Les langues disponibles

Les langues disponibles

System Setup options
System Setup Number and Description
125 = Temperature Indication Scale
200 = Heating System Type
205 = Heating Equipment Type
218 = Reversing Valve O/B
220 = Cool Stages / Compressor Stages
(200=Conv / 200=HP)
221 = Heat Stages / Backup Heat Stages
300 = System Changeover
NOTE: Once you have cycled through all of the System Setup numbers, press
Done to save and exit to the home screen.
Setup Complete
You have now finished installing and setting up your thermostat.
Options (factory default in bold)
0 = Fahrenheit
1 = Celsius
1 = Conventional Forced Air Heat
2 = Heat Pump
3 = Radiant Heat (Boiler)
5 = None (Cool Only)
Note: This option selects the basic system type your thermostat will
control.
Conventional Forced Air Heat:
1 = Standard Efficiency Gas Forced Air
2 = High Efficiency Gas Forced Air
3 = Oil Forced Air
4 = Electric Forced Air
5 = Hot Water Fan Coil
Heat Pump:
7 = Air to Air Heat Pump
Radiant Heat:
9 = Hot Water Radiant Heat
12 = Steam
Note: This option selects the equipment type your thermostat will
control. This feature is NOT displayed if feature 200 is set to Cool Only.
0 = O (O/B in Cool)
1 = B (O/B in Heat)
Note: This option is only displayed if the Heat Pump configured. Select
whether reversing valve O/B should energize in cool or in heat.
0, 1, 2
Note: Select how many Cool or Compressor stages of your equipment
the thermostat will control. Maximum of 2 Cool stages or 1 Compressor
stage. Set value to 0 if you do not have Cool Stage/Compressor Stage.
Heat Stages: 1, 2
Backup Heat Stages: 0, 1
Note: Select how many Heat or Aux/E stages of your equipment the
thermostat will control. Maximum of 2 Heat Stages for conventional
systems. Maximum of 1 Aux/E stage for systems with more than 1
heating equipment type. Set value to 0 if you do not have Heat Stage/
Backup Heat Stage.
0 = Manual
1 = Automatic
Note: Thermostat can automatically control both heating and cooling
to maintain the desired indoor temperature. To be able to select
"automatic" system mode on thermostat home screen, turn this feature
ON. Turn OFF if you want to control heating or cooling manually.
9
RTH5160 Series

Publicité

loading

Ce manuel est également adapté pour:

Rth5160d1016