Fitting the fire to an existing chimney

The fire can be fitted into an existing chimney providing
that the chimney / flue dimensions are 150 mm or more.
A special flue kit is required, which can be obtained
from Drugasar or a Drugasar agent. Do not use any
other type of flue system for this.
BS 5871 – 1 : 2001
Any chimney previously used for an appliance burning a
fuel other than gas shall be swept thoroughly before
installing any gas appliance.
Appliances shall be connected only to the types and sizes
of flue system as specified.
For any other information about this flue system please
contact Drugasar or Drugasar approved agent.

Baffle

To ensure that the heater works properly, the baffle should
be fitted in such a way that the heater can be adjusted
according to the customer's pipe system.
The baffle is supplied separately and should be fitted into
the heater as illustrated in fig. 7. Once it has been adjusted,
fix the baffle with the socket screw.
Adjusting the baffle:
• If the total length of the pipe system has been calculated
to between 1-12 m (examples 1, 2 & 3).
Baffle at 33 mm.
Slide the baffle in as far as it will go, the opening will auto-
matically be 33 mm.
• If connected with 1-1.5 m vertical pipe, a 90° bend and a
wall duct.
No baffle.
• If connected with 1-1.5 m vertical pipe, a 90° bend and
then 1-4 m horizontal pipe, as shown in example 4.
No baffle.
Fig. 3 illustrates how to calculate the total lengths.
fig. 7
INSTRUCTIONS FOR INSTALLATION

Connecting the Gas Supply

An approved connecting tap with coupling should be used
in the supply hose (In Belgium this must be B.G.V.
approved). Furthermore:
• Expel all air from the supply pipes/hoses before coupling
to the appliance.
• Do not turn the coupling tap when connecting it to the
gas supply.
• Avoid any pressure on the control tap and pipes.
• Check that all connections are gastight.

Fitting the glass panel

Once the logs are in place, the glass can be replaced in the
brackets nges and tightened with the two socket-head
bolts. In the event of damage or breakage, the glass should
be replaced immediately.
Mounting the front panel Colourline and
Quadro (fig. 9)
The frames for the Colourline and Quadro are packed
separately from the base set.
E
F
Colourline
E
Quadro
15
D
A
C
38c-1040
B
D
C
38c-1041
fig. 9
Colourline / Quadro / Avanto

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Quadro g31Avanto g31

Table des Matières