space all round the appliance in the fireplace to allow the
heat to escape; if this is not possible fit a convection con-
nection set, available as an accessory from your dealer.The
heater can also be installed in a corner, see fig. 1 for the
space this requires.

Mantel iron

An L-shaped mantel Iron can be ordered from your
installer.The mantel Iron, intended to support the brick-
work above the fire.This enables a stress-free installation
fig.4
fig. 1
INSTRUCTIONS FOR INSTALLATION
of the appliance. Fit the mantel iron as illustrated in fig. 2,
allowing 5 mm between the top of the appliance and the
bottom of the mantel iron, so that the packing cord pro-
vided seals adequately. Make sure that the front of the
heater (without the decorative facing) and the front of
the mantel iron are flush. Fitting the decorative facing will
hide the mantel iron from sight.
Mantel iron
Packing

Convection connection

The convection system of flexible pipes will enable the
heat to be spread to every corner of the room.The con-
nection materials can be ordered separately from your
dealer.
Possible connections (fig. 3)
The external duct can pass through either the wall or the
roof; the connections to both supply and flue pipes
should meet the following requirements:
• The first metre of pipe should always be installed
vertically.
• The horizontal length of pipe must never exceed 4 metres.
• The maximum length of vertical pipe is 12 metres.
Allow 2 metres for a bend of 90° and 1 metre for a 45°
bend.There is no need to allow for the length of the wall
or roof duct.
The maximum total length is the sum of the pipe lengths
plus the equivalent length for the bends (see the four
examples in fig. 3).
The roof duct set, the supply and flue pipes, the concen-
tric pipe and bends are packed individually and supplied
together with a clip binding with sealing ring.Tile flashing
or adhesive flashing is also available for use with a duct
through a slanting or flat roof respectively.