Outlet Valve; Pressure Control Valve; Typical Wear Parts - Titan POWRLINER 4500 Manuel D'entretien

Masquer les pouces Voir aussi pour POWRLINER 4500:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PL4500
2.3

OUTLET VALVE

1. Use a 22 mm wrench to remove the outlet valve from the
paint section.
2. Carefully remove the clasp (Fig. 27, pos. 1) using a
screwdriver. The compression spring (2) presses ball (4)
and valve seat (5) out.
3. Clean or replace the components.
4. Check the O-ring (7) for damage.
5. Check the installation position when mounting the spring
support ring (3) (clipped onto spring (2)), outlet valve seat
(5) and seal (6), refer to figure.
6. Torque the outlet valve housing to 37 ft.-lbs (50 Nm).
6
5
4
3
2
7
1
2.4

PRESSURE CONTROL VALVE

Only have the pressure control valve (1) replaced
by an Authorized Titan Service Center.
The max. operating pressure has to be reset by
an Authorized Titan Service Center.
1
2.5

TYPICAL WEAR PARTS

Despite the use of high-quality materials the highly abrasive
effect of the paints means that wear can occur at the following
parts:
INLET VALVE (spare part Order No.: 2411377)
For replacing refer to Section 2.2
(failure becomes noticeable through performance loss and/or
poor or no suction)
OUTLET VALVE (spare part Order No.: 2413371)
For replacing refer to Section 2.3
REPAIRS