––– STEP 6 –––
6.1 - INSTALL AND CONNECT PH200 PHOTOCELLS (fig. 14)
• position each photocell 40/60 cm above the ground • position
them on the opposite sides of the zone to be protected • position
them as close as possible to the gate (maximum distance = 15 cm)
• a tube for passing the cables must be present in the fastening
point • orient the TX transmitter towards the central zone of the
RX receiver (allowed misalignment: maximum 5°)
01. Remove the front glass (Phase 01 - Fig. 14)
02. Remove the upper casing then the internal casing of the photocell
(Phase 02 - Fig. 14)
03. Perforate the lower casing in the point where the cables should pass
(Phase 03 - Fig. 14)
14
01.
03.
05.
10 – English
04. - Position the lower casing in the point where the tube for the pas-
sage of the cables arrives and mark the perforation points (Phase
04 - Fig. 14)
- Use a percussion drill to drill the wall with a 5 mm bit. Insert the 5
mm wall plugs (Phase 04 - Fig. 14)
- Pass the electrical cables through the relevant holes and fasten the
lower casing with the screws (Phase 04 - Fig. 14)
05. - Connect the electrical cable to the terminals of the TX and RX,
which must be connected in parallel to each other then connected
to the terminal on the control unit (Fig. 12). It is not necessary to
observe any polarity.
- Put back in place, in the following order, the inner casing followed
by the upper casing to be fastened with the two screws then, lastly,
insert the cover and exert slight pressure to close it (Phase 05 - Fig.
14).
02.
04.
1
Led SAFE
2
3
4
Ø < 5 mm