Connection cable
• The hob is supplied with a connection cable.
• To replace the damaged mains cable, use the cable H03BB-F, H03V2V2-F or
H05V2V2-F for single phase connection or H05BB-F or H05V2V2-F for a two phase
connection. Speak to your local Service Centre. The connection cable may only be
replaced by a qualified electrician.
Connection diagram
220V-240V
220V-240V
Insert the shunts
Assembly
If you install the hob under a hood, please see the installation instructions of the hood for
the minimum distance between the appliances.
min.
500mm
If the appliance is installed above a drawer, the hob ventilation can warm up the items
stored in the drawer during the cooking process.
400V 2N
L1 L2
N
PE
between the screws as shown.
min.
50mm
220V-240V 1N
L
N PE
220V-240V
220V-240V
L L
N
N
PE
220V-240V
220V-240V