Installation

4.1 Specifications

Appliance type
FS 1/1 P with softener
FS 1/1 P with softener
FS 1/1 P without softener
FS 1/1 P with softener

4.2 Ambient conditions

Temperature:
7°C - 40°C
Humidity:
90% relative humidity of air,
non-consending.

4.3 Location / space requirements

- On genuine Salvis base or horizontal and stable
workbench.
- Level the appliance.
- Minor levelling adjustments can be made on the
adjustable feet. When the steamer is in its intended
location, it will need to be secured against sliding.
To do so use the 4 non-skid pads (they are enclosed
in the cooking chamber).
- Observe the following minimum clearances:
left and right 50 mm; rear 20 mm.
- Double deck version is not recommended.

4.4 Exhaust air

- The use of an extractor hood is not absolutely essen-
tial. Observe all the building and workplace regulations
which apply in your area.
- Heat absorbed:
latent
sensible 5000 kJ/H

4.5 Electrical connection

- Before connecting the device, check the information
provided on the type plate at the front of the right side
panel (when seen from the front of the appliance) and/
or on the inside of the appliance at the front left on the
interior panel. Observe all country-specific and local
regulations.
- THE DEVICE MUST ONLY BE CONNECTED BY A
QUALIFIED LICENSED ELECTRICIAN. All local
regulations must be complied with.
- An electrical diagram has been enclosed with the
appliance (interior, left wall).
- The appliance is supplied with approx. 1.5 m of cable
without a connector.
- To be provided on site: disconnector on all poles, with
at least 3 mm contact spacing.
- For connections and fuse ratings see 4.1.
- Each appliance requires its own fused supply cable.
- Connect the appliance to the potential equalisation.
The screw is located on the underside of the appliance
on the left: it is marked with the following symbol:
- Install a power socket near the appliance.
Power
Connections
12 kW
400V 3 N AC 5 x 2.50 mm2
15 kW
400V 3 N AC 5 x 2.50 mm2
15 kW
400V 3 N AC 5 x 2.50 mm2
15 kW
230V 3
3500 kJ/h
- 30 -
AC 4 x 6.00 mm2
4.6 Overpower protection system
(optional extra)
- The device includes a connection diagram with a
description of the connections. It is located on the left
side of the electrical compartment.

4.7 Water drainage

Lateral outlet with a separation gap
S team condensator
H ose
PE pipe
2 cm
open separation gap
- With steam-temperature resistant hose
Part lnumber: BI 278583
- Tube and hose at a constant gradient.
- Outlet open, leading into funnel.
- Funnel must not be directly underneath the appliance.
- Distance between outlet and top of the funnel 2 cm.
Fixed drainage connection with breather funnel
m in. 5 cm
- Install the hose at a constant gradient.
- Between Steamer and top of the funnel must be a
distance about 5 cm minimum.
- Do not connect an appliance without a breather
directly to the syphon trap.
Weight
Fuse ratings
20 A
102 kg
25 A
102 kg
25 A
97 kg
40 A
102 kg
G 3/4"
H ose
G 3/4"