Télécharger Imprimer la page

Konect MULTI 60+ Manuel D'utilisation page 4

Publicité

Les langues disponibles

Les langues disponibles

Types
Item
Standard Voltage
(V/Cell)
Max. charge voltage
cut off level (V/Cell)
Allowable fast charge current
Min. discharge voltage
cut off level (V/Cell)
6. Be sure to understand the information of the battery to be charged or discharged accurately. If the
program is set up incorrectly the battery can severely be damaged. Especially Lithium battery can cause
a fire or an explosion by over-charging.
7. To avoid short-circuits between the charge lead, always connect the charge cable to the unit first and only
then to the battery to be charged or discharged. Reverse the sequence when disconnection.
8. Do not connect more than one battery pack to charge at any one time.
9. Do not attempt to charge or discharge below types of battery:
a) Battery pack, which consists of different types of cell (including different manufacturers).
b) Battery, which is already fully charged or just slightly discharged.
c) Non-rechargeable batteries. (Explosion hazard)
d) Batteries that require a different charge technique from NiCd, NiMH, Lilon, LiPo, LiFe or Pb.
e) Faulty or damaged battery.
f) Battery fitted with an integral charge circuit or a protection circuit.
g) Batteries installed in a device, or which are electrically linked to other components.
h) Batteries that are not expressly stated by the manufacturer to be suitable for the currents the charger
delivers during the charge process.
10. Please check below point before charge operation.
a) Select the appropriate program which is suitable for the type of battery.
b) Set up adequate current for charging or discharging.
c) Lithium battery pack can be composed with parallel and series circuits mixed. You have to check the
composition of the battery pack carefully before charging.
d) Be sure all the connections firm and safe, on intermittent contact at any point in the circuit.
GENERAL NOTES ON OPERATING IT
Charging
A specific quantity of electrical energy is fed into the battery during charge process. The charge quantity
is calculated by multiplying charge current by charge time. The maximum permissible charge current
varies according to the battery type or its performance, and can be found in the information provided by
the battery manufacturer. It is only allowed to charge batteries at rates higher than the standard charge
current if they are expressly stated to be capable of quick-charge.
Connect the battery to charge to output terminal of the charger using suitable charge lead. They are red,
positive (+) and black, negative (-). Since the charger cannot detect the difference between the internal
4
Ni-Cd/Ni-MH
Li-Ion
1.2
3.6
4.1
1C-2C
1C or less
0.85 (Ni-Cd) -
2.5
1.0 (Ni-MH)
Li-Po
Li-Hv
3.7
3.8
4.2
4.35
1C or less
1C or less
3.0
3.0
Li-Fe
Pb
3.3
2.0
3.6
2.46
4C or less
4C or less
2.0
1.5
or higher
or higher

Publicité