Télécharger Imprimer la page

Konect MULTI 60+ Manuel D'utilisation page 11

Publicité

Les langues disponibles

Les langues disponibles

The screen displays the current state of charging. To stop the process, press Batt
type/Stop key once.
The audible sound indicates charge you the end of process.
DISCHARGING NICD/NIMH BATTERY
Set discharge current on the left and final voltage on the right. The discharge
NiMH[0] CHARGE A
current ranges from 0.1 to 2.0A and the final voltage ranges from 0.1 to 16.0V. To
CUR LIMIT
6.0A
start the process, press Start/Enter key for more than 3 seconds.
The screen displays the current state of discharge. You can alter the discharge
current by pressing Start/Enter key during the process. Once you change the current
value, store it by pressing Start/Enter button again.
To stop discharging press Batt type Stop key once. The audible sound indicates you
at the end of process.
CHARGE-TO-DISCHARGE & DISCHARGE-TO-CHARGE CYCLE NIMH/NICD BATTERY
Set the sequence on the left and the number of cycle on the right. You can use this function
NiMH[0] CYCLE
for balancing, refreshing and break-in the battery. To avoid rising temperature of the battery,
DCHG>CHG
3
there will a brief cool-off period that already fixed at "User setting" after each charge and
discharge process. The cycling number ranges from 1 to 5.
To stop the process, press Batt type/Stop key once. You can change the discharge
or charge current by pressing Start/Enter key once during the process. The audible
sound indicates you the end of process.
At the end of the process, you can see charged or discharged electric capacities of the
battery at each cyclic process.
By pressing INC or DEC button, the screen shows the result of each cycle in order.
PB (LEAD-SULPHURIC ACID) BATTERY PROGRAM
This is programmed for charging Pb (lead-acid) battery with nominal voltage from 2 to 12V. Pb batteries are totally
different from NiCd or NiMH batteries. They can only deliver relatively lower current compare to their capacity,
and similar restrictions definitely apply to charge. So the optimal charge current will be 1/10 of the capacity. Pb
batteries must not be charged rapidly. Always follow the instruction is supplied by the manufacturer of battery.
When you are willing to alter the parameter value in the program, press Start/Enter key to make it blink then change
the value with INC or DEC key. The value will be stored by pressing Start/Enter key once.
CHARGING PB BATTERY
Set up the charge current on the left and the nominal voltage of the battery on
Pb[0] CHARGE
the right. The charge current ranges from 0.1 to 6.0A and the voltage should be
4.0A
12.0V(6P)
matched with the battery being charged.
Start the charge process by pressing Start/Enter key for more than 3 seconds.
The screen displays the state of charging process. To stop charging forcibly, press
Batt type/Stop key once.
The audible sound indicates you at the end of the process.