Kohler K-1360 Mode D'emploi page 19

Masquer les pouces Voir aussi pour K-1360:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting Procedures (cont.)
Symptoms
10. Up/down volume control
arrows do not change
water flow as described.
11. Air flow through jets does
not stop when Tidepool
mode is activated.
12. Air continues to flow
through one or more jets
for several seconds after
Tidepool mode is
activated.
13. Pump stops before 18
minutes.
14. Pump does not
automatically stop after 22
minutes.
15. Pump won't turn off
when the power button
on user keypad is
pressed.
16. Pump operates but
variable speed feature
does not work.
17. Bath water cools while
pump is operating.
18. Noisy operation.
19. Remote control (if
equipped) does not work.
Kohler Co.
Probable Causes
C. Butterfly valve does not work.
D. Control does not work.
A. User keypad does not work.
B. Pump does not work.
C. Control does not work.
A. User keypad does not work.
B. Butterfly valve does not work.
C. Control does not work.
A. Normal operation - air will stop
flowing in a short time.
A. GFCI or ELCB tripped.
B. Suction is blocked.
C. Jets are blocked.
D. Motor overheated and
protection device activated.
A. 20-minute timer inadvertently
disabled.
A. User keypad does not work.
B. Control does not work.
A. Motor/pump does not work.
B. Control does not work.
A. Water temperature above 104°F
(40°C).
B. Heater is turned off on user
keypad.
C. Wiring from heater to control is
loose, disconnected or damaged.
D. Heater does not work.
E. Control does not work.
A. Pump banding straps have not
been cut.
B. Dry or dislodged jet O-ring
(squeal).
A. Batteries improperly installed or
dead.
B. Antenna on wiring harness is
damaged.
19
Recommended Action
C. Check wiring. Replace butterfly
valve.
D. Replace control.
A. Check wiring. Replace user keypad.
B. Check wiring. Replace pump.
C. Check wiring. Replace control.
A. Replace user keypad.
B. Check wiring. Replace butterfly
valve.
C. Check wiring. Replace control.
A. No action required.
A. Identify source of fault, and correct.
Reset GFCI or ELCB.
B. Remove obstruction.
C. Remove blockage.
D. Check for blockage at suction
and/or jets. Remove blockage and
allow motor to cool.
A. See service manual.
A. Replace user keypad.
B. Replace control.
A. Replace motor/pump.
B. Replace control.
A. Allow bath water to cool.
B. Turn heater on.
C. Check wiring for proper
connections.
D. Replace heater.
E. Replace control.
A. Cut pump banding straps with tin
snips.
B. Remove jet, replace and lubricate
O-ring, and reinstall jet.
A. Replace batteries.
B. Replace wiring harness.
1022211-2-C

Publicité

Table des Matières
loading

Table des Matières