7.0 -- Pump tubes to suction and discharge hoses
7.1
Place one end of the pump tube through the forward hole in the base
plate. Screw the mating suction hose onto the end.
7.2
Wrap the tube around the three rollers making sure the tube does not
overlap on itself.
7.4
Stretch the tube to allow the male end to go through the rear hole in the
mounting plate. Holding tension screw the mating discharge hose onto end.
7.6
Look to be sure there is clearance between the tire and the hose clamp. Repeat this
operation for the other side of the sprayer. Snug up the four connections to the pump
tubes using the 3/4" and 7/8" wrenches.