AC data
Type
Rated AC output
Maximum AC power
AC power connection
Cos phi
Maximum AC power
Fusing at AC end: Circuit breaker
THDI
Maximum efficiency
European efficiency
Supply from
Intrinsic consumption, night
Internal overvoltage protection
No longer available to order
1)
Cooling, ambient conditions, EMC
Type
Cooling
Ambient temperature during storage
and transport
Ambient temperature during
operation (with derating)
Maximum ambient temperature for
rated power
Installation altitude
Noise
Emitted interference
Manufacturer's declaration of
conformity
Interference immunity
Environmental classes
ENS
No longer available to order
1)
Mechanical properties
Type
Degree of protection
Dimensions: Width/height/depth
Minimum distances: Side/top/bottom
Weight
No longer available to order
1)
28
PVM10
PVM13
10 kW
12.4 kW
10 kW
12.4 kW
400 V 3 AC +N, 50 ... 60 Hz
1; may be set up to 0.9 with capacitive or inductive component
18 A
18.5 A
98.0 %
97.4 %
97.5 %
PVM10
PVM13
50 °C
Up to 2,000 m above sea level
EN 61000-6-4 for inverters in the industrial area
EN 61000-6-3 for inverters for the domestic, business and commercial
4K4H in accordance with IEC 60721-3-4
In accordance with VDE0126-1-1
PVM10
PVM13
IP65 in accordance with IEC 60529
530 mm / 601 mm / 270 mm
Approx. 40 kg
PVM17 4DC
PVM17 6DC
1)
16.5 kW
16.5 kW
25 A
32 A
< 2,5 %
97.7 %
60 W
< 0.5 W
Type 3 protection
PVM17 4DC
PVM17 6DC
1)
Natural convection
- 25 to + 70 °C
- 25 to + 55°C
45 °C
< 45 dBa
environments
CE
EN 61000-6-2
PVM17 4DC
PVM17 6DC
1)
50 mm / 500 mm / 500 mm
PVM20
16.5 kW
19.2 kW
16.5 kW
19.2 kW
29 A
29 A
98.2 %
97.8 %
97.8 %
PVM20
40 °C
PVM20
Approx. 41 kg