––– STEP 9 –––
9.1 - ADVANCED SETTINGS
9.1.1 - Parameter settings via radio transmitter
The radio transmitter can be used to set a number of control unit operat-
ing parameters: there are eight parameters.
1) Pause time: duration for which the leaves remain open (in the case of
automatic closure).
2) Pedestrian opening: pedestrian opening mode of the leaves.
3) Motor force: maximum force above which the control unit detects an
obstacle, and reverses the movement.
4) "Step-by-Step (SbS)" function: sequence of movements associated to
each "Step-by-Step" command.
Parameters
Pause time
Pedestrian opening
Motor force
Step-by-Step (SbS) function
(*)
Original factory value
Parameters
SbS input configuration on the control unit
Flash output configuration
Motor 1 and Motor 2 discharge in closure
Motor 1 and Motor 2 discharge in opening
(*)
Original factory value
12 – English

FURTHER INFORMATION

N° Valore
1
10s
2
20s (*)
3
40s
4
80s
1
Open 1 leaf halfway
2
Fully open 1 leaf (*)
3
2 leaves partially opened to 1/4 of the full course
4
2 leaves partially opened to half of the full course
1
Low
2
Medium low (*)
3
Medium high
4
High
1
"Open", "Stop", "Close", "Stop"
2
"Open", "Stop", "Close", "Open" (*)
3
"Open", "Close", "Open", "Close"
4
Open only
N° Value
1
Step-by-Step (*)
2
pedestrian opening
1
Flashing light (*)
2
Courtesy light
3
Gate open indicator
1
No discharge (*)
2
0.1s (Minimum)
3
0.2s
4
0.3s
5
0.4s (Medium)
6
0.5s
7
0.6s
8
0.7s (Maximum)
1
No discharge (*)
2
0.1s (Minimum)
3
0.2s
4
0.3s
5
0.4s (Medium)
6
0.5s
7
0.6s
8
0.7s (Maximum)
5) Discharging motor 1 when closing: adjusts the length of the "brief
reverse" of the motor after execution of the Close manoeuvre, in order
to reduce the final residual force.
6) Discharging motor 1 when opening: adjusts the length of the "brief
reverse" of the motor after execution of the opening manoeuvre, in
order to reduce the final residual force.
7) Discharging motor 2 when closing: adjusts the length of the "brief
reverse" of the motor after execution of the Close manoeuvre, in order
to reduce the final residual force.
8) Discharging motor 2 when opening: adjusts the length of the "brief
reverse" of the motor after execution of the opening manoeuvre, in
order to reduce the final residual force.
TABLE 3
Action: operation to be carried out at step 3 in
the recognition phase
Press T1 once
Press T1 twice
Press T1 three times
Press T1 four times
Press T2 once
Press T2 twice
Press T2 three times
Press T2 four times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
TABLE 4
Action to perform
Press T1 once
Press T1 twice
Press T2 once
Press T2 twice
Press T2 three times
Press T3 once
Press T3 twice
Press T3 three times
Press T3 four times
Press T3 five times
Press T3 six times
Press T3 seven times
Press T3 eight times
Press T4 once
Press T4 twice
Press T4 three times
Press T4 four times
Press T4 five times
Press T4 six times
Press T4 seven times
Press T4 eight times