Cleaning; Functional Inspection - Husqvarna K6500 Manuel D'utilisation

Masquer les pouces Voir aussi pour K6500:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cleaning

External cleaning
Clean the machine daily by rinsing it with clean water
after the work is finished.
WARNING! Do not use high-pressure
!
washers to clean the machine.

Functional inspection

General inspection
WARNING! Never use damaged cables.
!
They can cause serious, even fatal,
personal injuries.
Check that the cord and extension cord are intact and
in good condition. Never use the machine if the cord
is damaged, hand it in to an authorized service
workshop for repair.
Check that nuts and screws are tight.
Drive belt
Check the tension of the drive belt.
For correct tensioning of the drive belt, the square nut
should be positioned opposite the marking on the belt
cover.
Tensioning the drive belt
A new drive belt should be retightened after about one
hour's use.
The drive belt is enclosed and well protected from
dust and dirt.
When the drive belt is to be tensioned, release the
bolts holding the cutting arm.
22 – English
MAINTENANCE
Screw the adjuster screw so that the square headed
nut comes opposite the marking on the cover. This
automatically ensures that the belt has the correct
tension.
Replacing the drive belt
First release the two bolts and then the adjuster screw
to release the belt tension.
Now unscrew the bolts and dismantle the belt guard.
Remove the belt from the belt pulley.
The cutting head is now loose and can be removed
from the machine. Remove the rear belt guard by
releasing the two screws holding the guard.
Replace the drive belt.
Assemble in the reverse order as set out for
dismantling.
Drive wheel
Check the drive gear for wear.

Publicité

Table des Matières
loading

Table des Matières