Locking Lever Adjustment (fi g. 4)
WARNING: To reduce the risk of
injury, turn unit off and disconnect it
from power source before installing
and removing accessories, before
adjusting or when making repairs.
An accidental start-up can cause injury.
Excessive force should not be used to clamp the
locking lever. Using excessive force may damage
the base.
When the locking lever (i) is clamped the motor
should not move in the base.
Adjustment is needed if the locking lever will not
clamp without excessive force or if the motor moves
in the base after clamping.
To adjust the locking lever's clamping force:
1. Open the locking lever (i).
2. Using a hex wrench turn screw (s) in small
increments.
NOTE: Turning the screw clockwise tightens the
lever, while turning the screw counterclockwise
loosens the lever.
Centering the Subbase (fi g. 5)
WARNING: To reduce the risk of
injury, turn unit off and disconnect it
from power source before installing
and removing accessories, before
adjusting or when making repairs.
An accidental start-up can cause injury.
If you need to adjust, change, or replace the
subbase, a centering tool is recommended, refer to
Accessories. The centering tool consists of a cone
and a pin. To adjust the subbase, follow the steps
below.
1. Loosen but do not remove the subbase screws
(ll) so the subbase moves freely.
2. Insert the pin into the collet and tighten the
collet nut.
3. Insert the motor into the base and clamp the
locking lever on the base.
4. Place the cone on the pin (t) and lightly press
down on the cone until it stops as shown. This
will center the subbase.
5. While holding down on the cone, tighten the
subbase screws.
Using Template Guides
The plunge subbase will accept template guides.
On the fixed base an accessory subbase will be
needed to accept template guides. Recommended
accessories for use with your tool are available
at extra cost from your local dealer or authorized
service center.
NOTE: The D-shape subbase does not
accommodate template guides and is designed to
accommodate cutters up to 30 mm in diameter.
TO USE TEMPLATE GUIDES
1. Install template guide to subbase using two
screws and tighten securely.
2. Center the subbase. Refer to Centering The
Subbase.
Adjusting the Depth of Cut (fi g. 6)
WARNING: To reduce the risk of
injury, turn unit off and disconnect it
from power source before installing
and removing accessories, before
adjusting or when making repairs.
An accidental start-up can cause injury.
1. Select and install the desired cutter. Refer to
Cutter Installation and Removal.
2. Assemble base to motor, ensuring base is
attached to the depth adjustment ring (b). Place
router on the work piece.
3. Open the locking lever (i) and turn the depth
adjustment ring (b) until the cutter just touches
the work piece. Turning the ring clockwise
raises the cutting head while turning it
counterclockwise lowers the cutting head.
4. Turn the micro adjustable scale (h) clockwise
until the 0 on the scale lines up with the pointer
on the bottom of the depth adjustment ring.
5. Turn the depth adjustment ring until the pointer
lines up with desired depth of cut marking on
the micro adjustable scale.
NOTE: Each mark on the adjustable scale
represents a depth change of 0.5 mm and one
full (360º) turn of the ring changes the depth
12.7 mm.
6. Close the locking lever (i) to lock the base.
Using a Parallel Fence (fi g. 7A)
A basic parallel fence is included with the D26200,
D26204 and works well with fixed and plunge
bases. The basic parallel fence D262003-XJ is
available as an accessory for the other models and
may be purchased from your local retailer or service
center at extra cost.
1. Remove the motor unit from the base unit, see
Motor Quick Release.
EN G LI SH