Start & Stop Procedure - Belle Group BWR 650 Manuel De L'opérateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB
CAUTION
DO NOT let your hands off from the Starting Handle during the Starting procedures.
Before starting the engine, make sure that the Drive Lever is at Neutral, Vibration Lever is at OFF, and the Parking Lever is at ON
position.
1.
Open the fuel tap at the engine.
2.
Move the Throttle Lever at the Operation Handle to START position.
3.
Start the Engine – Electric Start
3a. Turn the Key Switch at the Throttle Lever to ST (Start) position, and hold it until the engine starts.
3b. When the ambient temperature is low, move the key to GL (Glow) position, and hold it for
approximately 10 seconds. Then move the Key to ST (Start) position and hold it until the engine
starts.
3c. After the engine has been started, make sure that the key is set to ON position during the
operation. (Setting the Key Switch to OFF position would not allow the generator to charge the battery.)
4.
Start the Engine – Manual Start
4a. Insert the Starting Handle to the starting bracket provided at the engine.
4b. While pulling the Decompression Lever with your left hand, rotate the Starting Handle slowly until you hear the sound of fuel
being injected.
4c. Release the Decompression Lever, and turn the Starting Handle with more force to start the engine.
5.
Move the Throttle Lever to LOW position, and let the engine run at idle for a few minutes to warm up.
6.
After the engine has warmed up, the machine is ready for operation.
7.
Move the throttle lever to the high speed "H" position quickly to prevent damage from occurring to the clutch. The "Full Throttle"
position of this machine has been preset at the factory to achieve optimum machine performance. DO NOT alter this setting
since premature wear or tear can result, and both engine and machine warranty will be automatically voided.
8.
Move the Parking Brake Lever to the right to disengage it.
NOTE: Negligence to disengage the Parking Brake before attempting to drive the machine forward or
reverse will result in the severe damage to the parking brake mechanism as well as the
drive system.
9.
Operators Control
9a. Throttle Lever
Always keep the Throttle Lever at High position during the operation. Do not attempt to alter the
travel speed by changing the engine revolution.
9b. Drive Lever
Move the Drive Lever forward to drive the machine forward. For reverse motion, move the lever
backward.
9c. Vibration Lever
By shifting the Vibration Lever to ON position, the vibration mechanism will be engaged, and
produce the vibration.
10. Stopping the Engine
11. In preparation for stopping the engine, move the throttle lever to LOW position.
12. Allow the engine to idle for 1-3 minutes.
13. Move the Throttle Lever to STOP position to stop the engine. Then, set the Key Switch to
"OFF" position.
The buzzer will sound when the Key Switch is set to ON while the engine is stopped.
14. Close the Fuel tap
15. Apply parking brake by swinging the Parking Brake Lever to the left.
Start / Stop Procedure
8
Glow
ON
OFF
Start
ON
CL
ST
OFF
Disengage
Drive Lever
Vibration Lever
Forward
Neutral
Reverse
Key Switch
Throttle Lever
Engage

Publicité

Chapitres

Table des Matières
loading

Table des Matières