Initial Operation - Scheppach SWP750 Traduction Des Instructions D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 32
• Check the proper status of the electri-
cal plug socket and make sure that the
plug socket is sufficiently fused (at least
6 A). Insert the pump plug into the plug
socket and the pump is ready for oper-
ation.
• Make sure that moisture or water nev-
er come in contact with the mains con-
nection.
• There is a risk of electrocution.

9. Initial operation

m IMPORTANT!
You must fully assemble the appliance
before using it for the first time!
Positioning/Hanging
• The dimensions of the pump shaft must
be not less than 45 x 45 x 45 cm, in or-
der that the float switch (3) can move
freely.
• The pump can be suspended by the
handle (1) or placed on the shaft floor.
The pump can be suspended and/or re-
moved using a rope.
• For safe suspension, loop the rope
around two of the holders of the han-
dle (1) and guide it upwards through the
handle (1).
• Never suspend the pump by the hose.
• Immerse the pump in the water to be
sucked in by forming an angle of 45
degrees (to reduce the amount of air
trapped in the pump body). If the pump
is resting on the floor, make sure that it
is on a flat and stable surface
• Make sure that there are no people in
the liquid to be pumped.
• Connect the pump to the mains.
28 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
Adjustment of the float switch
• The float switch (3) is set so that im-
mediate commissioning is possible.
For stationary installation the function
of the float switch (3) must be checked
regularly (at least every three months).
• The ON and OFF switching point of the
float switch can be adjusted by chang-
ing the position of the float switch in the
float switch grating. Please check the
following points before start of opera-
tion.
• The float switch must be attached so
that the switching point ON level and
the switching point OFF level can be
reached easily and with little expendi-
ture of energy.
• Check this by placing the pump into a
vessel filled with water and lift the float
switch carefully by hand and then low-
er it again. In this case, you can see
whether the pump switches on and off.
• Also ensure that the separation dis-
tance between the float switch head
and the float switch latching mecha-
nism is not too small. In the case of a
separation distance which is too small,
trouble-free
functioning
guaranteed.
• During the adjustment of the float
switch, ensure that the float switch
does not contact the floor before the
pump switches off.
• Attention! Risk of running dry and dam-
age to the device.
Electrical connection
The electrical motor installed is connect-
ed and ready for operation. The connec-
tion complies with the applicable VDE
and DIN provisions.
cannot
be

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

5909508901

Table des Matières