9. Initial operation

m IMPORTANT!
You must fully assemble the appliance
before using it for the first time!
• Install the equipment on a solid and lev-
el surface.
• Unscrew the coarse filter screw (6) and
remove the coarse filter (7) as shown
in Figure 2. Now you can fill the pump
housing with water via the coarse filter
screw (6). Filling the intake line acceler-
ates the in take process.
• Assemble in reverse order.
• Open the discharge line.
• Connect the mains cable.
• Switch on the equipment with the pow-
er switch (3) water can be suctioned in
for up to 5 minutes (max mum suction
height).
• After finishing the work, switch off the
equipment with the power switch (3)
Electrical connection
The electrical motor installed is connect-
ed and ready for operation. The connec-
tion complies with the applicable VDE
and DIN provisions.
Damaged electrical connection cable
The insulation on electrical connection
cables is often damaged.
This may have the following causes:
• Passage points, where connection ca-
bles are passed through windows or
doors.
• Kinks where the connection cable has
been improperly fastened or routed.
• Places where the connection cables
have been cut due to being driven over.
24 | GB
 www.scheppach.com /  service@scheppach.com /  +(49)-08223-4002-99 /  +(49)-08223-4002-58
• Insulation damage due to being ripped
out of the wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection ca-
bles must not be used and are life-threat-
ening due to the insulation damage.
Check the electrical connection cables
for damage regularly. Make sure that the
connection cable does not hang on the
power network during the inspection.
Electrical connection cables must comply
with the applicable VDE and DIN provi-
sions. Only use connection cables with
the marking „H05RN-F".
The printing of the type designation on
the connection cable is mandatory.
For single-phase AC motors, we recom-
mend a fuse rating of 16A (C) or 16A (K)
for machines with a high starting current
(starting from 3000 watts)!
AC motor 230 V~/ 50 Hz
Mains voltage 230 V~ / 50 Hz.
The mains connection and the extension
cable have to be three-core cables = P +
N + SL. - (1/N/PE).
Extension cables up tp 25m long must
have a minimum cross-section of 1.5
mm². Mains fuse protection is 16 A max-
imum.