Bear in mind
• Roller, ball and button galvanic probes are
interchangeable between them. To change a
probe, place the unit in standby mode, unscrew
the existing probe and screw the desired one.
• When the polarity is set for positive electrodes,
there will be a stinging sensation given off by
the roller probe that is stronger than the one
given off by the negative electrode. Select it
according to your needs.
• The selection of ion conduction to be used
should coincide with the pH of the product
applied.
- When the probe acts as a positive charge, the
conductive solution must be acidic (+).
- When the probe acts as a negative charge, the
conductive solution must be basic (-).
- If the pH is not indicated in the solution to be
used, use a pH indicator strip to determine it.
• If the Start/Stop indicator flashes, it means
that the circuit is not closed and there is no ion
conduction. Verify that the patient is holding
the metal bar.
● Spray and vacuum function
- Power and configuration
• In standby mode, press
spraying and suction function. The indicator
[SPRAY VACUUM] will light up green and on the
control panel:
- The timer will show 15 minutes.
- The power indicator will show 9
- The run / stop indicator will light red on the
push button
- Set the timer using the
choose the operating time of the machine, in
a range of between 1 and 30 minutes.
- Use the
button to start or stop the device.
-
- When in operation, the Start/Stop indicator
will light up green.
- When paused or in standby mode, the Start/
Stop indicator will light up red.
- Operation
• The unit must be in standby mode with the
Start/Stop indicator lit up red.
• Select the operating time.
• Spray function:
- Hold the spray tank in your hand and press
. The Start/Stop indicator lights up green.
- Lightly press the air outlet on the top of the
tank with your fingers to start spraying though
the nozzle.
• Vacuum function:
Bear in mind
to select the
or
buttons to
● Rotary brush function
- Firmly hold the vacuum handpiece in your
hands, place it in the desired position and
press
. The Start / Stop indicator will light
up green
- The nozzle of the head should meet the skin.
- Lightly press the air outlet of the handpiece
with your fingers to make the vacuum of the
skin in contact with the head.
• The device should be put in pause mode when
changing the vacuum tank or head.
• Prepare two spray tanks, for different liquids,
and you can alternate the tank according to your
needs.
• Make sure that the sponge filter is installed
on the end of the handpiece before starting
vacuum.
• Be careful when treating areas such as the
mouth, nose and eyes. The patient should keep
their eyes and mouth closed.
• The vacuum power should be kept under
control, as a high power could cause skin
lesions.
• Test first on your own hand, and then start with
the patient once the vacuum power has been
set.
• Select different heads for the different areas of
the skin:
- Small head: for small
areas of the skin
- Medium head: for narrow
areas of the skin.
- Large head: for large
areas of the skin.
• Regularly replace the sponge filter with a new
one.
- Power and configuration
• In standby mode, press
rotating brush function. The indicator
will light up green and on the control panel:
- The timer will show 15 minutes.
- The power indicator will show 5
- The clockwise rotation indicator
up.
to select the
will light
EN
11