Chapter 3
Troubleshooting
Troubleshooting (continued)

VFD

Symptom
Electric chain hoist
does not operate.
3

Interface Board

Symptom
Electric chain hoist
does not operate.

Braking Resistor

Symptom
Electric chain hoist
does not operate.
108
Cause
VFD failure
Reset the VFD by pressing Emergency
Stop button. It the VFD still does not
operate, check it.
Motor overheat
Stop by motor thermal relay function of
the VFD
Motor resumes operation when the VFD
is reset by pressing the Emergency Stop
after cool down.
VFD overheat
Stop by overheat preventive function of
the VFD
Motor resumes operation when the VFD
is reset by pressing the Emergency Stop
after cool down.
Expired service
Refer to the "VFD Manual".
life of the VFD
(capacitor)
Cause
Damaged circuit
Press the Push Button to check whether
component
LED on the board lights or not. If LED
does not light, replace the board.
This test is carried out with energizing
the VFD. Be careful about electric shock.
Contact failure of
Check the conduction of the connector.
connector
Replace the connector if it has no
conduction.
Cause
Resistor breakage
Measure the resistance of the resistor.
Replace the resistor if the resistance is
infinity.
Remedy
VFD failure
Operation exceeding
short time rating or
intermittent rating
Operation exceeding
short time rating or
intermittent rating
Operation exceeding
short time rating or
intermittent rating
Remedy
Over current, over
voltage, service life
expiry
Defective assembling
of the connector
Remedy
Operation exceeding
short time rating or
intermittent rating, over
load
Main factor
Countermeasure
Check the error code
indicated by VFD referring
to the "VFD Manual".
Check the short time rating
and intermittent rating.
Use the electric chain hoist
within these ratings.
Check the short time rating
and intermittent rating.
Use the electric chain hoist
within these ratings.
Check the short time rating
and intermittent rating.
Use the electric chain hoist
within these ratings.
Main factor
Countermeasure
Operate the electric chain
hoist at the rated voltage.
Replace the Interface
Board.
Crimp and insert the
connector pins securely.
Main factor
Countermeasure
Use the electric chain hoist
within the ratings.