Location of Ice Machine

The location selected for the ice machine must meet the
following criteria. If any of these criteria are not met, select
another location.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 50°F (10°C), but
must not exceed 110°F (43°C).
The water temperature must be at least 37°F (3°C), but
must not exceed 90°F (32°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must be capable of supporting the weight
of the ice machine and a full bin of ice.
The location must allow enough clearance for water,
drain and electrical connections in the rear of the ice
machine.
The location must not obstruct airflow through or
around the ice machine.

CLEARANCE REQUIREMENTS

Undercounter Units
Top
Sides
Back
NOTE: Allowance must be made for removal when the ice machine is built in. Monthly
removal of the top panel is required for cleaning & sanitizing.
Modular Units
Cooled
Top/Sides
8" (20 cm)
Back
5" (13 cm)
RCU Units
Front/Back
Sides/Top
Part Number 000007644 Rev 01 12/16

Installation Instructions

Air-Cooled
Water-Cooled
0" (0 cm)
0" (0 cm)
2" (5 cm)
2" (5 cm)
8" (20 cm)
8" (20 cm)
Air-
Water-
QuietQube
Cooled
Air-Cooled
8" (20 cm)
0" (0 cm)
5" (13 cm)
0" (0 cm)
Remote Condensing Unit
24" (61 cm)
6" (15.2 cm)
Section 2

Installation Requirements

The ice machine and bin must be level.
Vent the ice machine and bin drains separately.
Bin drain termination must have an air gap.
A backflow preventer is required on water inlet lines.
The ice machine and bin must be sanitized after
installation.
Local water conditions may require treatment of the
water to inhibit scale formation, filter sediment, and
remove chlorine odor and taste.
Routine adjustments and maintenance procedures
outlined in this manual are not covered by the warranty.

Ice Machine Heat of Rejection

Series
Ice Machine
RF0244 - RF0266
RFS0300
RNS0308
RF0388 - RF0399
RFS0650 - RNS0600
RNS1000
RNS1078C - RFS1200
RN1278C - RFS1279R
RN1400
RF2300 - RFS2300
Ice machines, like other refrigeration equipment, reject
heat through the condenser. It is helpful to know the
amount of heat rejected by the ice machine when sizing air
conditioning equipment.
This information is also necessary when evaluating the
benefits of using water-cooled or remote condensers to
reduce air conditioning loads. The amount of heat added to
an air conditioned environment by an ice machine using a
water-cooled or remote condenser is negligible.
Knowing the amount of heat rejected is also important
when sizing a cooling tower for a water-cooled condenser.
Use the peak figure for sizing the cooling tower.

Rack Unit Connection Size

Model
RFS1279R
RFS2379R
Heat of Rejection
Heat of Rejection
A/C Btuh
Peak Btuh
2400
3075
3500
5200
7500
7500
16000
17000
Suction Line
Liquid Line
5/8 inch
3/8 inch
(15.9 mm)
(9.5 mm)
3/4 inch
1/2 inch
(19 mm)
(12.7 mm)
5000
4100
5200
7700
10900
14000
16400
29500
9

Publicité

Chapitres

Table des Matières
loading

Table des Matières