Starting operation
4.5
Cleaning preserving agent when starting-up
of operation initially
1. Immerse the suction tube (Fig. 7, Item 1) and return hose (2)
into a container with a suitable cleaning agent.
2. Turn the pressure control knob counterclockwise (3) to
minimum pressure.
(k circulation).
7. Pull the trigger of the spray gun.
8. Spray the cleaning agent from the unit into an open collecting
container.
4
4.6
Taking the unit into operation with coating
material
1. Immerse the suction tube (Fig. 7, Item 1) and return hose (2)
into the coating material container.
2. Turn the pressure control knob counterclockwise (3) to
minimum pressure.
(k circulation).
7. Trigger the spray gun several times and spray into a collecting
without interruption.
8. Increase the pressure by slowly turning up the pressure
control knob.
Check the spray pattern and increase the pressure until the
atomization is correct.
Always turn the pressure control knob to the lowest setting
with good atomization.
9. The unit is ready to spray.
p spray).
5
3
1
2
p spray).
GB
4.7

Digital Electronic Spray Control (DESC)

The Digital Electronic Spray Control (DESC) increases the functionality
of the sprayer. It is installed directly below the pressure control
knob on the control panel. It consists of a display and four function
keys. The display shows various menu screens that allow the user to
customize and monitor sprayer operation using the function keys.
Display
Function
Keys
The pressure control knob overrides the Digital
i
Electronic Spray Control (DESC) settings. Anytime the
pressure control knob is turned, the sprayer pressure
will change accordingly.

Function Keys

The function keys are numbered 1–4. Each key is labeled with an
additional function as well.
performs a function described on the active menu screen.
#2/ Key
screen or increases a value.
#3/ Key
screen or decrease a value.
#4/Select Key
function described on the active menu screen.
Menu Screens
Several menu screens are available for the user to customize and
Security Code, Prime, and Rapid Clean.
Main Screen
the control system at sprayer startup.
Pressing the #2 key switches between PSI, Bar, and MPa units
of measure.
screens.
For sprayers equipped with an nine-language Digital
i
Electronic Spray Control (DESC):
Pressing the #2 key at the Main Screen switches
between PSI, Bar and MPa units of measure.
Pressing the #3 key at the Main Screen changes
the language of the text on the display. There are
a total of nine languages available. Each time the
The languages, in order of appearance, are: English,
Spanish, Dutch, Danish, Swedish, German, French,
Italian, and Portuguese.
30
SET MPa
23.0
ACTUAL MPa
22.5
SET MPa
ACTUAL MPa
23.0
22.5

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Prospray 3.31