Monitor Connector Description - golmar Stadio Plus T500SE ML Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

MONITOR ADJUSTMENTS
Locate the CN4 connector, that's placed in the monitor base. Remove the
existing jumper and plug the EL562 module.
NOTE: on this type of installations the EL500SE microprocessed circuit
must be setting with SW1-3 to ON (page 112). Refer to the specific
installation diagram.
H
andling the end of line jumper.
The end of line jumper is placed on the CN4 connector, that can be
located on the monitor base.
In case of twisted pair cable installations, the end of line jumper is
placed in the EL562 module, also located in the CN4 connector of the
monitor base.
Do not remove the jumper on monitors where the video cable finish.
Remove the jumper on monitors where the video cable continue.
C
hanging the front film.
The monitor is supplied with a reversible front film, that allow the owner
to choose between two colors.
To change the front film, remove the front plate by inserting a plain
screwdriver in the triangle marks, as it is shown on the drawing.
121
E
L562 module for video installations
with twisted pair cable.
122

MONITOR CONNECTOR DESCRIPTION

a
b
Colocar la parte superior de la regleta a 1,60m. del suelo.
Place the top part of the monitor connector at 1,60m. from the floor.
REF
RCPL-PLUS
b
a
a. Wall attachment hole (x4).
b. Monitor attachment hook (x2).
c. Vertical wiring input.
d. Attachment clip.
e. Wiring input hole.
f. Installation terminals:
+, –:
positive, ground.
Vin :
video signal coaxial input.
Malla:
coaxial shield.
Vout :
video signal coaxial output.
A :
audio communication.
D :
digital communication.
HZ- :
door bell push button input.
INT :
intercom.
SA :
auxiliary calling device output.
CTO :
video distributor activation output.
2C :
2nd camera activation output.
A1 :
optional device activation output.
Vp, Mp :
twisted pair video signal.
Terminals +, – and Malla (shield) are duplicated for easiest cascade installation of parallel
monitors or telephones. If the first monitor is not placed on the connector, cascade units will not
be powered.
D
escription of the RCPL-Plus
monitor connector.
c
d
50mm.
V
in
50mm.
Malla
Shield
Malla
e
Shield
V
out
A
Presionar para abrir.
D
Press to open.
HZ-
f
INT
SA
CTO
2C
A1
11758882
CODE
VP
LOTE
MP

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

0111

Table des Matières