Télécharger Imprimer la page

Klein Tools CL210 Manuel D'instructions page 3

Publicité

Les langues disponibles

Les langues disponibles

function
ac Voltage
(V ac)
Dc Voltage
(V Dc)
input impedance: 10MΩ
frequency range: 45 to 400Hz
Maximum input: 600V AC RMS or 600V DC
ac current
(a ac)
frequency range: 50 to 60Hz
resistance
Maximum input: 600V AC RMS or 600V DC
temperature
otHer MeaSureMent applicationS
Maximum input: 600V AC RMS or 600V DC
• continuity check: Audible signal <10Ω, max current 1.5mA
• Sampling frequency: 3 samples per second
• auto power off: After ~15 minutes of inactivity
• overload: "OL" indicated on display
• polarity: "-" on display indicates negative polarity
• Display: 3 ½ digit, 2000 Count LCD
electrical SpecificationS
range
200.0mV
2.000V
20.00V
200.0V
600V
200.0mV
2.000V
20.00V
200.0V
600V
2.000A
20.00A
200.0A
400A
200.0Ω
2.000KΩ
20.00kΩ
200.0kΩ
2.000MΩ
20.00MΩ
-40° to 1832°F
-40° to 1000°C
resolution
0.1mV
1mV
10mV
100mV
1V
0.1mV
1mV
10mV
100mV
1V
1mA
10mA
100mA
1A
0.1Ω
10Ω
100Ω
1kΩ
10kΩ
≤0°F ±(2.8% + 12 digits)
1°F
1°C
accuracy
±(2.5% + 10 digits)
±(2.0% + 5 digits)
±(1.0% + 8 digits)
±(1.0% + 3 digits)
±(2.5% + 30 digits)
±(2.0% + 10 digits)
±(1.2% + 5 digits)
±(1.2% + 3 digits)
±(2.0% + 5 digits)
>0°F ±(2.8% + 6 digits)
±(2.8% + 6 digits)