Télécharger Imprimer la page

salmson SUBSON Serie Manuel D'installation Et Mise En Service page 17

Publicité

Les langues disponibles

Les langues disponibles

ENGLISH
SUBSON 10 and AB
4 The suction strainer is screwed to the pump housing,
– Loosen 4 screws (Ø4 x 60),
– Remove suction strainer, handle O-ring (Ø155 x 2)
between suction strainer / pump housing with care.
10. FAULTS, CAUSES AND REMEDIES
Only have faults remedied by qualified personnel!
Observe safety instructions in 9 Maintenance.
Fault
The pump does not start or stops
during operation
Pump does not switch on/off
Pump does not pump
Flow rate drops during operation
If the fault cannot be remedied, please contact the trade or
your nearest Salmson-After-sales Service or agent.
11. SPARE PARTS
Spares should be ordered through local trade outlets and/or
the Salmson-After-sales Service.
To avoid queries and incorrect orders, all the data on the
name plate must be indicated when ordering.
Subject to change without prior notice!
Cause
Current supply interrupted
Motor protection switch has tripped
Fluid temperature too high
Pump silted up or blocked
Float switch blocked or cannot move freely
Air in the installation cannot escape
Water level below the intake port
Pressure pipe / hose diameter too small (losses
too high)
Non-return valve sticking in the pressure port
Hose kinked / check valve closed
Suction strainer blocked / impeller blocked
17
5 Clean the impeller and pump housing under running water.
The impeller must turn freely.
6 Replace damaged or worn parts with original spares.
7 Re-assembly the pump in the reverse order.
Remedy
Check fuses, cables and electrical connec-
tions.
Allow the pump to cool down, it will start
again automatically
Allow to cool down
Disconnect the pump from the mains and
remove from the shaft.
Remove the suction strainer and rinse the
suction strainer / impeller under running
water
Check float switch and ensure mobility
Place the pump at an angle in water briefly
until the air escapes.
Vent the installation / drain if necessary
Dismantle suction strainer / whirl device, rinse
suction strainer / vent slit under running
water.
Check the switch-off level "h1"
If possible, submerge the pump deeper
(observe the switch-off level)
Bigger dimensioning of the pressure pipe /
hose diameters
check function
Clear kink in hose / open check valve
Disconnect the pump from the mains and
remove from the shaft.
Remove the suction strainer and rinse the
suction strainer / impeller under running
water.

Publicité