3.0 PRE-INSTALLATION PREPARATION

3.1

APPLIANCE PLACEMENT

EN
Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review
your installation plans and/or installation.
Draw out a detailed plan of the installation including dimensions and verify the dimensions with the require-
ments listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 48" (1219.2mm) of the front of the appliance.
3.2

CLEARANCE TO COMBUSTIBLES

(CEILING OF ENCLOSURE TO APPLIANCE BOTTOM, EXCLUDING HEARTH HEIGHT).
PARALLEL & CORNER
SIDEWALL (A)
SIDEWALL TO FLUE (B)
BACK WALL (C)
BACK WALL TO FLUE (D)
CORNER (E)
CEILING (F)
Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply
with NFPA 211 or CAN/CSA-B365.
3.3

FLOOR PROTECTION

If the appliance is to be installed on top of a combustible fl oor, it must be guarded by a non-combustible material
extending at least 18" (457mm) from the front and 8" (203mm) from the sides and back of the appliance, see
"CLEARANCE TO COMBUSTIBLES" section.
Refer to local building codes for suitable fl oor protection materials.
K
J
I
W415-1473 / 04.22.15
DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET (2.1m)
BACK WALL
D
C
A
B
CANADA
J
USA
NOTE: If a section of horizontal chimney connector is used, fl oor protection is
required under the chimney connector and 2" (51mm) beyond each side.
WARNING
!
BACK WALL
E
E
SINGLE WALL CONNECTOR
22" (559mm)
31 3/4" (806mm)
12" (305mm)
15 1/2" (394mm)
8" (203mm)
84" (2134mm)
MINIMUM FLOOR PROTECTION
FRONT (I)
18" (457mm)
16" (406mm)
67.1B
F
DOUBLE WALL CONNECTOR
22" (559mm)
31 3/4" (806mm)
12" (305mm)
15 1/2" (394mm)
8" (203mm)
84" (2134mm)
SIDES (J)
BACK (K)
8" (203mm)
8" (203mm)
8" (203mm)
8" (203mm)