Have an authorized dealer install the appliance. If you install the appliance yourself, have your dealer review your
installation plans and/or installation. Draw out a detailed plan of the installation including dimensions and verify the
dimensions with the requirements listed in this manual.
You may wish to adjust the appliance position slightly to ensure the vent does not intersect with a framing
member. Appliance must be positioned so that no combustibles are within, or can swing within (e.g. drapes,
doors), 48" (121.9cm) of the front of the appliance.
Inserts only: This appliance is equipped with levelling screws, level the appliance before installing into the fi nal
position. Levelling the appliance will eliminate rocking or excessive noise when the fan is in operation. Once the
appliance is level, move it partially into place to allow for all connections to be made. It is not practical to level the
appliance once it has been installed. Determine the required depth prior to installing the appliance and adjust the
levelling screws accordingly.
3.2

minimum clearance to combustibles

WARNING
!
Do not install into any area having less than 7 feet (2.1m) (ceiling to appliance bottom, excluding hearth
height).
PARALLEL & CORNER
Sidewall (A)
Sidewall to flue (B)
Backwall (C)
Backwall to flue (D)
Corner (E)
Ceiling (F)
Clearances can be reduced with shielding acceptable to local authorities. Reduced installation must comply with
NFPA 211 or CAN/CSA-B365.
3.3
alcove installation
BACK WALL
Your appliance may be installed, using a listed
D
C
double wall connector, such as Security DL6 in
Canada, the Simpson Duravent Plus DVL in the
A
USA or an equivalent double wall connector,
B
into an alcove having a depth of no more than 4
feet and a height of at least 6'3". The minimum
clearances are as shown.
PARALLEL & CORNER
Ceiling (F)
K
NOTE: Minimum width 64" (1626mm), Minimum depth 32" (813mm)
J
J
I
BACK WALL
D
C
A
B
SINGLE WALL CONNECTOR
K
J
J
I
BACK WALL
E
E
SINGLE WALL CONNECTOR

3.0 installation planning

BACK WALL
E
E
19" (48.3cm)
28 7/8" (73.3cm)
17 1/2" (44.5cm)
21" (53.3cm)
11" (279mm)
84" (213.4cm)
F
ALCOVE
N/A
installation planning
41.1
F
DOUBLE WALL CONNECTOR
19" (48.3cm)
28 7/8" (73.3cm)
12 1/2" (31.8cm)
16" (40.6cm)
7" (178mm)
75" (190.5cm)
19"
A
B
(482.6
48" (1219.2mm)
mm)
28
/
"
7
ALCOVE
8
(733.4mm)
DOUBLE WALL CONNECTOR
75" (190.5cm)
W415-1463 / E / 08.20.18
EN
MAX