Placement of the compressor in the cabinet
DK50 2V/50S (Fig. 3 A)
Disassembly cabinet door
Remove the door held by 2 screws and disconnect the grounding lead.
Compressor placement
Remove the connecting strip (33) in front of the cabinet.
Before placing the compressor without the dryer (DK50 2V/50) into the cabinet, please
follow Chapter 12.3 to add sound insulation foam into the cabinet.
Insert the compressor into the cabinet using the positioning truck (35), place the connecting
strip in front of the cabinet and adjust the position of the compressor so that the two "V"
notches on the connecting strip align with the compressor legs.
This puts the compressor in the right position for the cabinet. Insert the compressor into the
cabinet only so far as to be able to install the connecting strip and so the compressor
doesn't obstruct its installation.
Insert the compressor with a dryer into the cabinet so that the dryer fan fits into the cooling
tunnel opening in the cabinet. WARNING, do not insert the compressor down to the stop.
For dryer versions of the compressor, the flow of cooling air into the cooler will be restricted
and there is a risk of permanent damage to the dryer.
Place the connecting strip (33) in its original position in the lower part of the cabinet.
Cabinet door installation
Align the door with the cabinet, connect the grounding lead to the door and install the door to the
cabinet using 2 screws.
A compressor with air dryer must not be inserted to the cabinet to the stop as
there is a risk of permanent damage to the dryer.
DK50 2x2V/110S (Fig. 3 B)
Opening the upper cover
Lift the upper cabinet cover grabbing it by its handle (31) so that the gas springs keep the
cover open.
Be careful when closing the cabinet cover – there is a risk of closing it on your
fingers.
Disassembly of the front cabinet panel (Fig. 3 B)
Remove the door held by 4 screws and disconnect the grounding lead.
Inserting the compressor (Fig. 3 B)
Insert the compressor into the cabinet so that the pressure air outlet faces the operator.
Insert the compressor with a dryer into the cabinet so that the dryer fan fits into the cooling
tunnel opening in the cabinet.
Cabinet door installation
Align the door with the cabinet, connect the grounding lead to the door and install the door
to the cabinet using 4 screws.