Télécharger Imprimer la page

Max SuperStapler TA551B/16-11 Manuel D'instructions D'utilisation page 5

Agrafeuse pneumatique
Masquer les pouces Voir aussi pour SuperStapler TA551B/16-11:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

2. AIR SUPPLY AND CONNEC-
TIONS (Fig.2)
A. TOOL AIR FITTINGS/COUPLINGS:
This tool uses a 1/4" N.P.T. male plug. The inside diameter
should be .28" / 7mm or larger. Install a male plug on the tool
which is free flowing and which will release air pressure from the
tool when disconnected from the supply source.
B. OPERATING PRESSURE:
70 to 100 p.s.i. / 5 to 7 bar. Select the operating air pressure with-
in this range for best performance based upon the fastener appli-
cation and work surface. Using the lowest acceptable to minimize
noise, vibration and wear.
DO NOT EXCEED 120 p.s.i. / 8 bar.
C. HOSES1:
Hose has a min. diameter of 1/4" / 6 mm and max. length of no
more than 17' / 5 m.
The supply hose should contain a fitting that will provide "quick
disconnecting" from the male plug on the tool.
D.SUPPLY SOURCE:
Use only clean regulated compressed air with pressure regulated
not to exceed maximum air pressure marked on the tool.
If regulator fails, maximum air pressure delivered to tool shall
not exceed 200 p.s.i / 13.8 bar or 1.5 times maximum air pres-
sure, whichever is greater.
E. 3-PIECE AIRSET2(Air filter
To optimize performance use a 3-piece air set 2. A filter 3 will
help to get the best performance and minimum wear from the tool
because dirt and water in the air supply are major causes of wear
in the tool.
Frequent, but not excessive, lubrication (one drop in every 100-
200staples) is required for the best performance. Oil added thru
the air line connection will lubricate the internal parts.
3. INSTRUCTIONS FOR OPERA-
TION
1.
BEFORE OPERATION
Check the following prior operation.
1
Wear Safety Glasses or Goggles.
2
Do not connect the air supply.
3
Inspect screw tightness.
4
Check operation of the contact arm & trigger if moving
smoothly.
5
Connect the air supply.
6
Check the air-leakage. (The Tool must not have the air-
leakage.)
7
Hold the Tool with finger-off the trigger, then push the con-
tact arm against the work-piece. (The tool must not oper-
ate.)
8
Hold the Tool with contact arm free from work-piece and pull
the trigger. (The Tool must not operate.)
9
Disconnect the air supply.
2.
OPERATION
STAPLE LOADING
1
(Fig.3) Pull pusher 1 back into "locked" position.
2
(Fig.4) Insert the staples 1 into the magazine 2.
3
(Fig.5) Hold the click lever 1 and put back the pusher.
, Regulator
, Oiler
):
3
4
5
TEST OPERATION
1
Adjust the air pressure at 70 p.s.i. / 5bar and connect the air
supply.
2
Without touching the Trigger, depress the Contact Arm
against the work-piece. Pull the Trigger. (The tool should
fire the fastener.)
3
With the tool off the work-piece, pull the Trigger. Then de-
press the Contact Arm against the work-piece. (The tool
should fire the fastener.)
4
Adjust the air pressure as much as the lowest possible ac-
cording to the diameters and length of fastener and the
hardness of work-piece.
DRIVING FASTENERS
This tool is shipped with CONTACT ACTUATION selected. It is
the responsibility of employer, tool owner or tool operator to se-
lect the appropriate actuation system for the fastener application
and training of tool operator before changing the trigger setting.
SWITCHING CONTACT ACTUATION TO SEQUENTIAL ACTU-
ATION (Option)
To change the trigger system, please contact MAX CO., LTD. au-
thorized distributors and have them change the system.
SWITCHING SEQUENTIAL ACTUATION (Option) TO CON-
TACT ACTUATION
To change the trigger system, please contact MAX CO., LTD. au-
thorized distributors and have them change the system.
CONTACT ACTUATION OPERATION
For contact actuation operation, hold the Trigger and depress the
Contact Arm against the work surface.
SEQUENTIAL ACTUATION OPERATION (Option)
For sequential actuation operation, activate the Contact Arm
against work surface and pull the Trigger. A fastener will be driv-
en.
CONTACT ACTUA-
TION
SEQUENTIAL AC-
TUATION
CONTACT ACTUA-
TION
SEQUENTIAL AC-
TUATION
3
PROCEDURE
1
Pulling the Trigger and keeping it
pulled.
2
Depressing the Contact Arm.
The tool fires a nail each time when the
Contact Arm is depressed.
The tool cannot fire a nail.
PROCEDURE
1
Depressing the Contact Arm.
2
Pulling the Trigger and keeping it
pulled.
The tool fires a nail.
The tool fires a nail.
In order to fire a second nail, you should
both release the Trigger and remove the
Contact arm from the surface.

Publicité

loading

Ce manuel est également adapté pour:

Superstapler ta551a/16-11ceSuperstapler ta551a/16-11