Adjustments

3

- Test the Safety Reversal System

Without a properly installed safety reversal system, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
• Safety reversal system MUST be tested every month.
• After ANY adjustments are made, the safety reversal system
MUST be tested. Door MUST reverse on contact with 1-1/2"
(3.8 cm) high object (or 2x4 laid flat) on the floor.
1
With the door fully open, place a 1-1/2 inch (3.8 cm) board (or a 2x4
laid flat) on the floor, centered under the garage door.
2
Press the remote control push button to close the door. The door
MUST reverse when it makes contact with the board.
If the door stops but does not reverse:
Repeat Program the Travel (see Adjustment Step 1);
1.
Repeat the Safety Reversal test.
2.
If the test continues to fail, call a trained door systems technician.
4

- Test the Protector System

Without a properly installed safety reversing sensor, persons
(particularly small children) could be SERIOUSLY INJURED or
KILLED by a closing garage door.
1
Open the door. Place an obstruction in the path of the door.
2
Press the remote control push button to close the door. The door will
not move more than an inch (2.5 cm).
The garage door opener will not close from a remote control if the LED in
either safety reversing sensor is off (alerting you to the fact that the sensor
is misaligned or obstructed).
If the garage door opener closes the door when the safety reversing sensor
is obstructed (and the sensors are no more than 6 inches [15 cm] above
the floor), call for a trained door systems technician.