Troubleshooting (cont.)
Symptoms
2.
The green LED light is on,
but there is no steam from
the steam head.
3.
There is a continuous
flow of water from the
steam head. Water flow
during the power clean
cycle is normal.
4.
Steam is coming out of
the steam head and the
control is shut off.
Warranty
KOHLER Steam Generator
THREE-YEAR LIMITED WARRANTY
Kohler steam generator units manufactured after September 15, 2001, are warranted to the original consumer
purchaser to be free of manufacturing defects in material and workmanship during normal residential usage
Kohler Co.
Probable Causes
A. The water is turned off.
B. The inlet screen is plugged.
C. Excessive back pressure caused
by too long a run of piping or
too many 90° elbows.
D. Water blockage due to a steam
trapway in the steam line. A
steam trapway is caused by
steam line piping running down
from the steam generator and
then back up to the steam head.
E. The steam control is not
connected.
A. Internal steam generator
components are not working.
B. The water supply is incorrectly
connected to the steam
generator.
A. Elevations over 6000' (1829 m)
above sea level can cause water
to boil at lower temperatures.
15
Recommended Action
A. Turn on the water supply.
B. Remove and clean the inlet screen.
C. Move the steam generator closer to
the steam head or use 45° elbows.
D. Change the steam pipe to slope
down from the steam head to the
steam generator.
E1. Check the wiring connections
according to the steam control
installation and care guide.
E2. Use the troubleshooting kit
attached to the steam generator to
troubleshoot connection problems.
A1. Shut off the water supply, and
drain the water from the steam
generator. Close the drain valve.
A2. Partially open the water supply
shut-off valve.
A3. Allow the water to gradually fill
the steam generator tank (may take
several minutes). If the water
continues to flow from the steam
head, repeat A1 above.
A4. Fully open the water supply
shut-off valve.
A5. On models with power clean
option only: If water continues to
flow from the steam head, run the
power clean cycle.
A6. If water continues to flow from the
steam head, contact the Customer
Care Center using the information
on the back of this guide.
B. Review this manual, and if
necessary reconnect the water
supply to the proper location.
A. At elevations over 6000' (1829 m)
above sea level contact Kohler Co.
Customer Care Center for
instructions on disconnecting the
fast start coil.
1230487-2-E