STEINEL NM 5000-2-24 Consignes D'installation page 7

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12
Troubleshooting
Problem
Cause
No power at the
breaker has tripped;
sensor
short circuit
Lights do not
light level setting is in
switch ON
nighttime mode during
daytime operation
lamp burned out
power is off
breaker has tripped
low voltage wiring to
power pack incorrect
power pack is in
manual on mode
www.steinel.net
(800) 852-4343
Remedy
reset breaker, check
wiring with voltage
tester
check for proper
wiring connections
adjust light level
setting
replace lamp
turn power on at
circuit breaker
reset breaker
check for proper
wire connections
place power pack in
automatic on mode
Troubleshooting
Problem
Cause
Lights do not
surroundings not yet
switch OFF
bright enough
Lights do not
Set morning function is
switch ON in the
disabled
morning
Lights switch ON
changeover between
at unusual time
summer/winter time
switching times are
incorrect
Remedy
Wait until it is light
enough; if
necessary, define a
new light
ON brightness (in
the evening)
Set morning
function to ON (fully
clockwise)
change setting
if necessary
(switching times
are automatically
adjusted based on
sunrise/sunset not
time of day)
redefine ON value
(switching times will
be recomputed)
www.steinel.net
(800) 852-4343