Installation instructions, only for experts
To install the operating unit, perform the following steps:
1. Prepare an installation cut-out (213 x 82 mm) in the wall of the sauna.
2. Place the installation frame A into the installation cut-out.
3. Affi x the installation frame by bending the fi xing plates D outwards using
a screwdriver.
4. Lay the RJ-12 cable in the wall of the sauna room, leading it from the power
unit installation location to the installation cut-out for the operating unit.
5. Connect the plug of the RJ-12 cable to the connection socket on the rear
of the operating unit.
6. Place the operating unit C into the installation frame A.

4.3. Installing the heater sensor F1 with excess temperature fuse

Observe the following points when installing the heater sensor:
● The heater sensor must be installed on the rear of the heater, above the mid-
dle of the sauna heater. An interval of approx. 15 cm to the roof of the sauna
room must be maintained.
● The heater sensor must be attached in a way that it is not affected by a fl ow
of air.
To install the heater sensor, perform the following steps (see Fig. 4):
1. Lay the two 2-pin heater sensor wires in the wall of the sauna room, leading
them to the heater sensor installation location and affi x the heater sensor
wires using wire clips.
2. Pull the two half-shells
3. Connect the four connectors for the heater sensor wire
with the Fig. 4.
4. Place the connection panel
sensor half-shells.